6.3. Operation
Push the big black button on top of the
Filtertrolley 2.0 to turn the device on.
Check whether the connections are made properly and whether the blow-out nozzles are open.
If your device possesses the optional airflow controller, you may adjust the suction capacity
with the potentiometer.
The optionally installed “loaded filter indicator” shows the current state of the filter. As long
as the LED glows green the
Filtertrolley 2.0 is in normal mode. The filters are
saturated when the LED changes to red.
Then proceed as described in section 7.
7. Maintenance and Filter Replacement
The maintenance confines itself to the check of the filter contamination state and the
replacement of the filter. Devices with the optionally installed “loaded filter indicator” signal
with their LED the required filter replacement.
LED: -green-
filter is in good condition
LED:
-red-
filter
replacement
necessary: - replacement of the pre-filter mat
If no improvement takes place:
- replacement of the whole filter
The picture illustrates a filter replacement in lying
position. Before the filter can be taken out, the
black draw latches have to be unlocked, and the
cover needs to be removed.
Available filter types: LRA
LAS
ACD
ASD
Disposal: professional;
according
to valid regional regulations
Attention:
The device has to be unplugged before repairs, maintenance, or filter
replacements are carried out!
- The device is subject to inspection for portable
electrical equipment.