Chapter 5: Operating Instructions
Configure
Part No. 24001157
VersaMux-4000 Operation & Installation Guide
Page 5-17
Revision C
provides descriptions for the
Aggregate
parameters and options.
Table 5-5
Aggregate Parameter and Option Descriptions
Parameter
Options and Description
Card Type
The system displays the card type installed.
NOTE:
Release 1.0 software only supports an NRZ module as the aggregate.
Function
NOTE:
Changing and activating this parameter resets the port rates to 0 (zero) kbps.
The options for the
Function
parameter are:
4-Port-Mux
- The VersaMux-4000 functions as a trunk group multiplexer. This option
configures the VersaMux-4000 to multiplex the traffic from each port onto the
aggregate.
Port-1-Relay
- The VersaMux-4000 relays the traffic between Port-1 and the
aggregate. This option configures the VersaMux-4000 as a protocol converter with the
port running at the aggregate rate.
Port-2-Relay
- The VersaMux-4000 relays the traffic between Port-2 and the
aggregate. This option configures the VersaMux-4000 as a protocol converter with the
port running at the aggregate rate.
Port-3-Relay
- The VersaMux-4000 relays the traffic between Port-3 and the
aggregate. This option configures the VersaMux-4000 as a protocol converter with the
port running at the aggregate rate.
Port-4-Relay
- The VersaMux-4000 relays the traffic between Port-4 and the
aggregate. This option configures the VersaMux-4000 as a protocol converter with the
port running at the aggregate rate.
Mode
The options for the
Mode
parameter are:
Disabled –
The system disables the aggregate interface.
DCE -
The NRZ connector uses the DCE signals as described in the EIA-530-A
specification. See
and
for a description of the NRZ control lead behavior when
in DCE mode.
DTE
The NRZ connector uses the DTE signals as described in the EIA-530-A
specification. See
and
for a description of the NRZ control lead behavior when
in DTE mode.
(page 1 of 3)