2M-Z8514, Ultra-Max Electric Griddle

GENERAL INFORMATION

This equipment is designed and sold for commercial use only by personnel trained and experienced 

in its operation and is not sold for consumer use in and around the home nor for use directly by the 

general public in food service locations.  For equipment to be used by the general public, please 

contact the factory.

INSTALLATION

The griddles are equipped for the voltage indicated on the nameplate mounted on the front panel.  

They will operate on alternating current (AC) only. 

DO NOT CONNECT TO DIRECT CURRENT (DC).

The installation of the electric griddle should conform to the:

NATIONAL ELECTRIC CODE AND ALL LOCAL ELECTRIC CODES AND 

ORDINANCES AND THE LOCAL ELECTRIC COMPANY RULES AND 

REGULATIONS

For your protection we recommend that a qualified electrician install this griddle.  He should be 

familiar with electrical installations and all electric codes.  Proper connections and power supply are 

essential for efficient performance.  The external wiring should be in conduit or an approved type 

of flexible cable suitable for operation at the temperature indicated on the wiring diagram, and of a 

proper size to carry the load.  The supply circuit should be properly fused and equipped with a means 

of disconnecting, as required by local electrical code.  THE BODY OF THE GRIDDLE SHOULD BE 

GROUNDED (DO NOT GROUND TO A GAS SUPPLY LINE).

EXHAUST CANOPY

Griddles inherently create a good deal of heat and smoke and should be installed under an efficient 

exhaust hood with flame proof filters. A vertical distance of not less than 48” shall be provided 

between the top of the appliance and filters or any other combustible material.  Exhaust installation 

must conform to local codes.

AIR SUPPLY: 

Provisions for adequate air supply must be provided. 

GENERAL OPERATING PROCEDURES

The Ultra-Max series electric griddles may be wired for operation in the field for either 1-phase or 

3-phase power supplies by making line connections at the junction box(es) located at the rear of the 

unit.  Models 724T-230/400V, 736T-230/400V & 748T-230/400V, should be wired for 3-phase power 

supply only.  Two junction boxes are provided on the 760T & 772T for making line connections.  

CONNECTING POWER SUPPLY

Detach cover on junction box at rear of unit.  There is a terminal block for the supply connection in the 

junction box.  Wires can be rerouted in the terminal block for 3phase hook-up.  See wiring diagrams 

and model voltage on unit panel

LOCATING AND LEVELING THE UNIT

Do not install the unit closer than 1-inch from a side wall and/or closer than 1-inch from a rear 

wall.  Make sure the unit is properly ventilated.  Level unit by adjusting the (4) feet which have an 

adjustment of 1-3/4” (43.75mm) for accurate leveling and perfect line-up with other Ultra-Max series 

units.

CAUTION

WARNING

Summary of Contents for 724TA

Page 1: ...TA Not approved for Canada ANSI NSF 4 ELECTRIC GRIDDLES MODELS 724TA 736TA 748TA 760TA 772TA CHROME MODELS 724TCHSA 736TCHSA 748TCHSA 760TCHSA 772TCHSA Installation and Operation Instructions 2M Z1621...

Page 2: ...ate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks i...

Page 3: ...code THE BODY OF THE GRIDDLE SHOULD BE GROUNDED DO NOT GROUND TO A GAS SUPPLY LINE EXHAUST CANOPY Griddles inherently create a good deal of heat and smoke and should be installed under an efficient ex...

Page 4: ...d now be ready for use Even with careful seasoning food may to some extent stick to the griddle cooking surface until the griddle plate is broken in TEMPERATURE CONTROL The temperature controls are co...

Page 5: ...rming at top efficiency DO NOT allow grease to accumulate as it will carbonize and become difficult to remove To prevent this condition the following cleaning suggestions should be followed 1 Remove e...

Page 6: ...ls or abrasive cleaners abrasive pads product identifiers and point of sale attachments or any other non food object tha comes in continuous contact with the roller coating This warranty does not appl...

Page 7: ...IELD WIRING GROUND WIRE TERMINAL BLOCK 3 PHASE FIELD WIRING GROUND CONNECTOR GROUND WIRE THERMOSTAT HEATING ELEMENT PILOT LIGHT 3 6 5 4 2 NOMINALAMPS PER LINE 3 PH 208V 3 PHASE X 36 2 Y Z 36 2 36 2 24...

Page 8: ...SYSTEM OPERATING AT MORE THAN 250 VOLTS TO GROUND 230 400 VOLT Y 13 05 KW X Y Z 2M Z8552 REV A 2 20 07 32 7 32 7 9 8 7 6 5 4 3 2 1 Y Z 15 14 15 14 15 14 32 7 NOM AMPS PER LINE N 16 16 16 16 16 16 16...

Page 9: ...T Y 21 75 KW X Y Z 31 5 31 5 16 16 16 15 14 10 12 7 5 4 3 2 1 Y Z 15 14 15 14 15 14 31 5 NOM AMPS PER LINE N 16 16 16 16 16 16 16 16 16 11 17 17 17 13 13 13 13 N G G 16 16 16 15 14 7 17 13 16 16 16 15...

Page 10: ...11 12 13 20 22 23 24 25 26 27 21 14 15 17 18 19 16 5 4 2 3 29 28 CERTAIN INSTANCES MAY NOT BE AVAILABLE ILLUSTRATIVE PURPOSES ONLY AND IN SOME ITEMS ARE INCLUDED FOR MODEL 724TA 736TA 748TA 760TA 772T...

Page 11: ...MINAL LUG 14 2 AL CU 1 208 240V 9 G5 824023 JUNCTION BOX ASSY 1 208 240V G5 Z10348 ELECTRICAL BOX 230V 10 G5 824021 BODY ASSY 24 1 11 2N Z8484 HEATING ELEMENT 4350W 208V 2 208V 2N Z8485 HEATING ELEMEN...

Page 12: ...AL LUG 14 2 AL CU 1 208 240V 9 G5 824023 JUNCTION BOX ASSY 1 G5 Z10348 ELECTRICAL BOX 230V 10 G5 836019 BODY ASSY 36 1 11 2N Z8484 HEATING ELEMENT 4350W 208 3 208V 2N Z8485 HEATING ELEMENT 4350W 240 2...

Page 13: ...ERMINAL LUG 14 2 AL CU 1 208 240V 9 G5 824023 JUNCTION BOX ASSY 1 208 240V G5 Z10348 ELECTRICAL BOX 230V 10 G5 848019 BODY ASSY 48 1 11 2N Z8484 HEATING ELEMENT 4350W 208 4 208V 2N Z8485 HEATING ELEME...

Page 14: ...8 2E Z8423 TERMINAL LUG 14 2 AL CU 2 208 240V 9 G5 824023 JUNCTION BOX ASSY 2 208 240V G5 Z10348 ELECTRICAL BOX 1 230V 10 G5 860012 BODY ASSY 760T 230V 1 230V G5 860019 BODY ASSY 60 208 240V 11 2N Z8...

Page 15: ...OVER 2 7 2E Z8482 TERMINAL BLOCK 2 8 2E Z8423 TERMINAL LUG 14 2 AL CU 2 9 G5 824023 JUNCTION BOX ASSY 2 10 G5 872019 BODY ASSY 72 1 11 2N Z8484 HEATING ELEMENT 4350W 208 6 208V 2N Z8485 HEATING ELEMEN...

Page 16: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: