30
Regeneration Modes
Rev D
4. Regenerate. Used to command the controller to regenerate. Also used
to change the lock mode.
Programming Conventions
The 700 series controller is programmed using the buttons on the keypad.
The programming instructions will be described two ways whenever a
section has keypad input.
First, a table shows simplified instructions. Second, text follows that
describes the action. In each table:
"Action" lists the event or action desired.
"Keys" are listed as:
UP for up arrow
DOWN for down arrow
SET for set
REGEN for regeneration
"Duration" describes how long a button is held down:
P/R for press and release
HOLD for press and hold
X sec for a number of seconds to press the button and hold it down
"Display" calls out the display icons that are visible.
Regeneration Modes
The 700 Series controllers can be regenerated either automatically or
manually. During a regeneration, the total time remaining of the
regeneration will be displayed on the controller. The current cycle is shown
in the lower left of the display.
To Initiate a Manual Regeneration:
•
Press REGEN once for delayed regeneration. System will regenerate at
next set regen time (2:00 AM).
A flashing regen (recycle) symbol will be displayed.
•
Press and hold REGEN for 5 seconds to initiate immediate manual
regeneration. A solid regen symbol will be displayed.
•
After immediate regeneration has begun, press REGEN again to
initiate a second manual regeneration. A flashing "x2" symbol
indicates the second regeneration will start at the time of
regeneration. Press and hold REGEN to turn on the second
NOTE:
If a button is not pushed for thirty seconds, the controller returns
to normal operation mode. Pushing the Regenerate button immediately
returns the controller to normal operation.