Regeneration Modes
31
Rev D
regeneration immediately following the current regeneration. The
double regeneration is indicated by the "x2" symbol being on steady.
During a Regeneration:
•
A "C#" is displayed to show current cycle.
•
Total regen time remaining is displayed on screen.
•
Press and hold SET to show current cycle time remaining.
To Advance Regeneration Cycles:
•
Press and hold SET - showing current cycle time.
•
Simultaneously press SET and UP to advance on cycle. An hourglass
will display while cam is advancing.
When cam reaches next cycle, "C2” will be displayed.
•
Repeat SET and UP to advance through each cycle.
•
Press and hold SET and UP for 5 seconds to cancel regen.
Hourglass will flash once cancelled.
Camshaft will advance to home – may take 1 to 2 minutes.
Regeneration Cycles:
•
C1 – Backwash
•
C2 – Regeneration Draw/Slow Rinse (not used in filter mode)
•
C3 – Slow Rinse (not used in filter mode)
•
C4 – System Pause (to repressurize tank)
•
C5 – Fast Rinse cycle 1
•
C6 – Backwash cycle 2 (not used in filter mode)
•
C7 – Fast Rinse cycle 2 (not used in filter mode)
•
C8 – Regenerant Refill (not used in filter mode)
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
C
Capacity
Hardness
MIN
x2
Total regen time remaining