Initial Start-up Step-By-Step Instructions
35
Rev D
•
To program the regenerant amount, press SET to enter the change
mode. The 9 (lbs/ft
3
) default will begin to flash. Use UP and DOWN to
scroll through the available settings. Press SET to enter the amount.
•
Filter backwash time (filter mode only)
If the system is set up as a filter, regenerant amount is unnecessary.
The controller deactivates the regenerant amount setting, and
changes to an adjustable backwash time in minutes.
•
Press SET to change the time.
•
The default time of 14 minutes will begin to flash.
•
Use UP and DOWN to select the appropriate backwash time for
the media type and amount used. The controller can use 0 to 99
minutes for backwash.
•
Press SET again to enter that time.
Table 1- High Efficiency Exchange Capacity
Salt
lbs/cu ft
Exchange
Capacity
grains/cu ft
Salt grams/
liter
Exchange
Capacity
grams/liter
3
14100
50
33.6
4
18307
60
40.0
5
21160
70
44.5
6
23490
80
48.4
7
25460
90
51.8
8
27167
100
54.9
9
28673
110
57.7
10
30019
120
60.2
11
31238
130
62.6
12
32350
140
64.8
13
33373
150
66.8
14
34320
170
70.4
15
35202
200
75.2
16
36027
230
79.3
17
36802
260
82.9
18
37533
290
86.1
Table 2
To Convert Capacity in
Into Capacity in
Multiply by
kilograms (kg)
kilograins (kgr)
15.43
kilograins (kgr)
kilograms (kg)
0.0648
moles of CaCO3
kilograms (kg)
0.10
equivalents of CaCO3
kilograms (kg)
0.05
Time & Day
Regen Time & Day
Backwash Time
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness