742/762 SERIES ADVANCED PROGRAMMING
43
Rev D
742/762 SERIES ADVANCED PROGRAMMING
The 700 Series controllers are designed to operate by only setting the time
of day and the day of the week. The remaining settings have been set at
the factory. These default settings will work for most applications.
To change a setting:
Action
Key
Duration
Display
Enter basic
programming
SET
Press and
Release
Will show time and day
of week
Move to desired
display
UP or DOWN
arrows
Press and
Release
Will increment through
the displays
Enable setting to be
changed
SET
Press and
Release
Display will flash
Change setting
UP or DOWN
arrows
Press and
Release
Value changes and
continues to flash
Save setting
SET
Press and
Release
Display stops flashing
Return to operation
REGEN
Press and
Release
Normal operation
display
View history values
SET and
DOWN
Press and
Hold for 5
seconds
HO will be displayed
Level II Advanced
Programming
UP and DOWN
Press and
Hold for 5
seconds
P1 will be displayed
For Regeneration
SET
UP arrow
DOWN
arrow