www.ultraoptics.com
page 8
Two Lens Cycle Screen
Use the following procedure to begin the two lens cycle:
1. Select ON/OFF button to put it in the ON position
a. At this time, the vacuum will turn on
2. After pre-cleaning, center the front side of the lens on the suction cup that is above the
wash bowl
a.
When facing the machine, this is on the operator’s right side as shown in Figure
6 on previous page.
3. Remove hand from the lens and out of the machine and the wash cycle will start
4. When wash cycle is complete, the spindle arm assembly will lift up, index to the next
position
5. After pre-cleaning, center the front side of the second lens on the suction cup that is now
above the wash bowl (the first lens will now be on the left side of the machine)
6. Remove hand from the lens and out of the machine and the spindle arm assembly will
drop down
a. The coating cycle will start on the first lens and the wash cycle will start on the
second lens
7. When this cycle is complete, the spindle arm assembly will lift up, index to the next
position
a. The first lens will now be in the curing position
b. The second lens will now be in the coating positon
8. When this cycle is complete, the spindle arm assembly will lift up, index to the next
position
a. The first lens will now be cured and will index over to the wash station and will
remain on the suction cup (lens will not be re-washed)
b. The second lens will now be in the curing positon
9. When this cycle is complete, the spindle arm assembly will lift up and index to the next
position with both lenses cured. Place a hand on each lens and then depress the foot
switch to release the vacuum and remove the two completed lenses from the machine.
10. Select the ON/OFF button to reset the two lens program.