www.ultraoptics.com
page 26
PLC OUTPUTS
PLC INPUTS
Y0: Lamp high mercury switch
X1: Vacuum spindle 1
Y1: Vacuum spindle 1
X2: Vacuum spindle 2
Y2: Vacuum spindle 2
X3: Cylinder up
Y3: Cylinder up
X4: Cylinder down
Y4: Cylinder down
X5: Light curtain
Y5: Wash pump
X6: Lamp home
Y6: Air jet
X7: Lamp extend
Y7: Spindle 1 coat (on/off)
X8: Foot pedal
Y8: Spindle 2 coat (on/off)
X9: Index home
YA: Spindle 1 wash
XA: Index position
YB: Spindle 2 wash
XB: Lamp door
YC: Coat spin off
YD: Cure lamp motor
Y301: Lamp on/off
Y302: Coating pump
Y303: Wash motor
Y304: Dump valve
Y305: Index motor
Y306: Lamp fans
PANASONIC
FP-X C30R
PANASONIC
FP-X E16R
XE
XC
XA
X8
X6
X4
X2
X0
COM
XF
XD
XB
X9
X7
X5
X1
X3
COM
YD
YB
C4
Y8
Y6
Y5
C2
Y3
C1
C0
YC
YA
Y9
Y7
C3
Y4
Y2
Y1
Y0
X7
X5
X3
X1
COM
COM
X6
X4
X2
X0
COM
COM
Y7
Y5
Y4
Y2
Y1
Y0
Y6
C3
Y3
C2
C1
C0