www.ultraoptics.com
page 21
2. Select MACHINE SET UP
3. Select REMOVE LAMP
4. Select LAMP REMOVE
5. Turn machine power off at the red switch on the front panel
6. Disconnect power cord from the back of the machine
7. Open the back service door of the machine
8. Remove the two pan head phillips screws that hold the
UV light module in place
9. Remove the UV light module by pulling on the handle
10. Allow lamp to sit for ten minutes to cool
11. Remove the lens from the lamp area when cool
12. Check for lens debris and ensure the reflectors are
clean.
a. If reflectors are not clean and cannot be cleaned,
contact Ultra Optics and replace module with a new one.
13. Plug module back into carriage
14. Secure with two screws removed in step #8
15. Close back service door
16. Reconnect power cord at back of machine
17. Turn machine power back on
Flushing coating
1. Perform steps #1 -
#6 of “Replacing coating filter” procedure
2. Follow the black tube up to the coating reservoir and disconnect. Both coating tubes
should now be disconnected.
3. The coating reservoir can now be unscrewed and removed from the coating bowl for
easy cleaning.
4. Once the coating reservoir is removed from the machine, flush it with acetone and allow
it to dry. Ensure any debris in the coating reservoir has been removed. If not, flush
again.
5. Unscrew and discard coating filter
6. Wipe out coating bowl using a clean, lint free cloth that is damp with acetone
7. Make sure the coating bowl screen, located on the bottom of the bowl, has been cleaned
before reassembling
8. Apply Teflon tape on both ends of the new coating filter before reattaching the fittings.
Take care to not get tape on the first thread of the fitting.
9. Connect both elbows with the nuts on the tubing with the arrow pointed up.
10. Snap the filter into the clip
11. When the coating system has been reinstalled and all tubes are connected, pour new
coating into the coating bowl and check for leaks
12. Re-prime the system using the following steps and check for leaks:
a. Select COAT ON/OFF and the system will pump coating into the container.
While the pump is running, slowly crack the bleed valve on top of the filter to
Figure 11 - UV Lamp removal
screws