3. Select LAMP REMOVE
4. Turn machine power off at the red switch on the front panel
5. Disconnect power cord from the back of the machine
6. Open the back service door of the machine
7. Remove the two pan head phillips screws that hold the UV light module in place
8. Remove the UV light module by pulling on the handle
9. Insert new light module
10. Secure with two screws removed in step #7
11. Turn machine on and check to be sure lamp is in home position
Spindle Suction Cups
1. Turn suction cup until 1.5mm set screws line up with holes in chuck assembly
2. Insert 1.5mm allen wrench into set screws to lock shaft
3. With shaft locked, turn suction cup to the left to remove
4. Thread new suction cup onto chuck shaft
Replacing sensors
Prox Sensors Index, and Lamp Home and Extend
1. Disconnect Signal cable
2. Loosen jam nut
3. Unscrew sensor
4. Replace with new sensor and jam nut
5. Adjust sensor depth until it is 2mm away from flagging mechanism
6. Tighten jam nut
7. Reconnect signal cable
Lift cylinder up and down sensor
1. Make a mark on the lift cylinder at the top and bottom of bad sensor
2. Disconnect signal cable from sensor
3. Loosen set screw on sensor
4. Slide bad sensor to the bottom of groove to remove bad sensor
5. Insert new sensor and slide into position between markings
6. Tighten set screw on sensor
7. Reconnect signal cable
Vacuum Sensor
1. Disconnect air tubes going into sensor
2. Disconnect signal cable
3. Connect signal cable to new sensor
4. Connect air tubes to new sensor
5. Program sensor as per instructions