background image

If both numbers are identical you can start 

charging process. If not, press BATT TYPE/ 

STOP button to go back to previous screen 

to recheck the number of cells of the battery 

pack before going ahead.

This screen shows the real-time status during 

charge process. Press BATT TYPE/STOP 

button once to stop the charge process.

At this screen, you can set up the current

and voltage of the battery pack. Charging

and discharging will make the batteries

come to the voltage level of storage state.

This screen displays the number of cells you

set up and the processor detects. 

R=Number of cells detected by charger. 

S=Number of cells set by you at the previous 

screen. 

If both numbers are identical you can start 

charging process by press START/ENTER 

button. If not, press BATT TYPE/STOP 

button to go back to previous screen to 

recheck the number of cells of the battery 

pack before going ahead.

'STORAGE' CONTROL OF LITHIUM BATTERY

This function is for charging/discharging batteries which are not used at 

once. This program is designed for charging or discharging of batteries 

of specific original state. They are classified by types: 3.75V Lilon, 

3.85V LiPo and 3.3V LiFe. The program will begin to discharge if the 

original state of battery exceeds the voltage level of storage.

Start

Enter

Start

Enter

Batt type

Stop

>3 seconds

DEC.  INC.

DEC.  INC.

Number

of

cells

Charging

time

Charge

current

Supplied

capacity

Current

voltage

battery

- +

- +

LITHIUM BATTERY(LiPo/LiFe/LiIon)PROGRAM

17

Summary of Contents for UP100AC QUAD

Page 1: ...UP200AC DUO 2x200W AC DC 12 0A Multi Charger UP100AC QUAD 4x100W AC DC 10 0A Multi Charger INSTRUCTION MANUAL Multi Charger Built in Power Supply UP200AC DUO UP100AC QUAD 400W AC DC 400W AC DC ...

Page 2: ... Discharging Lithium Battery 18 Pb Battery Program 19 Charging of Pb Battery 19 Discharging of Pb Battery 19 NiMH NiCD Battery Program 20 Charging of NiMH NiCD Battery 20 Charging NiMH NiCD Battery in the Auto Charge Mode 20 Charging NiMH NiCD Battery in re peak Charge Mode 21 Discharging of NiMH NiCD Battery 21 Charge Discharge Discharge Charge Cycle of NiMH NiCD Battery 22 Battery Memory Set 23 ...

Page 3: ...e operating area Make sure you know the specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged Fire or explosion can occur due to overcharging This warranty is not valid for any damage or subsequent damage arising as a result of a misuse or failure to observe the proce...

Page 4: ...el or 7 4V in series Have you checked that all connections are firm and secure Make sure there are no intermittent contacts at any point in the circuit Standard Battery Parameters Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries Incorrect settings could cause the cells to fire or explode 3 7V cell 4 2V cell 3 8V cell 1C 3 ...

Page 5: ...15cells 2V 20V 1 10cells 300mA cell 2 4kg 244 199 76mm Charge power Discharge power Charge current range Discharge current range LiIo LiPo LiFe cell count NiCd NiMH battery cell count Pb battery voltage Current drain for balancing LiPo Weight Dimension UP200AC DUO Specification UP100AC QUAD Specification AC 100 240V DC 11 0 18 0V 4x100W 400W 4x10W 40W 0 1 10 0A 0 1 5 0A 1 6 series 1 15cells 2V 20V...

Page 6: ...TRODUCTION 5 LCD Screen Battery Sockets Battery Sockets DC Input 11 18V DC Balance Socket Temp Sensor PC Link DC Output 5V 1A AC Input 100 240V AC Cooling fan with Temp Sensor Control Menu Control Buttons ...

Page 7: ...ance Socket DC Input 11 18V DC AC Input 100 240V AC Cooling fan with Temp Sensor Control LCD Screen Battery Sockets Battery Sockets Battery Sockets Battery Sockets Temp Sensor Temp Sensor Temp Sensor Menu Control Buttons ...

Page 8: ...e battery individually Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal Adaptable to Various Type of Lithium Battery UP200AC DUO UP100AC QUAD is adaptable to various types of lithium batteries such as LiPo LiIon and the new LiFe series of batteries Fast and Storage Mode of Lithium Battery Purposes to charge lithium batter...

Page 9: ...threshold the process will be terminated automatically Automatic Charging Current Limit You can set up the upper limit of the charging current when charging your NiMH or NiCd battery it is useful for the NiMH battery of low impedance and capacity in the AUTO charging mode Capacity Limit The charging capacity is always calculated as the charging current multiplied by time If the charging capacity e...

Page 10: ...t the charge lead should be of adequate conductor cross section and high quality connectors which are normally goldplated should be fitted to both ends Always refer to the manual by the battery manufacturer pertaining to charging methods Operate according to their recommended charging current and charging time lithium batteries in particular should be charged strictly according to the manufacturer...

Page 11: ...es to protect them Some rechargeable batteries have a memory effect If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their capacity next time This is a memory effect It is said that NiMH and NiCD batteries are suffering from memory effect NiCD has more memory effect than NiMH Lithium batteries are recommended to be disc...

Page 12: ...ng any battery it is absolutely essential to check one last time that you have set the charging parameters correctly If the settings are incorrect the battery may be damaged and could even burst into flames or explode Check that your wiring is correct polarity from the charger to your battery double check to be safe To avoid short circuiting a battery you must always connect the charge leads to th...

Page 13: ...n doubt as to which socket to use please ask your dealer for clarification 5 Start the charge cycle wait and watch that the charger starts to charge and shows correct readings on the screen 6 When charging is finished disconnect the balance lead from the board then disconnect the battery main leads from the charging lead This diagram shows the correct way to connect your battery to the UP200AC DUO...

Page 14: ...CURRENT 3 3A DSCHCURRENT 1 5A DSCHVOLTAGE 1 7V CELL SAVEPROGRAM ENTER PROGRAMSELECT PbBATT ENTER START PbCHARGE 2 0A 2 0V 1P PbDISCHARGE 0 1A 2 0V 1P PROGRAMSELECT NiCDBATT NiCDCHARGE CURRENT 2 0A ENTER START NiCDDISCHARGE 0 1A CUT 1 0V NiCDCYCLE CHG DCHG 1 PROGRAMSELECT NiMHBATT ENTER START NiMHCHARGE CURRENT 2 0A NiMHDISCHARGE 0 1A CUT 1 0V NiMHCYCLE CHG DCHG 1 PROGRAMSELECT LiPoBATT LiPoBALANCE...

Page 15: ...ODE This function is for balancing the voltage of lithium polymer battery cells while charging In the balance mode the battery needs to connect to the battery s power lead with balance wire In this mode the charging process will be different from ordinary charging mode The internal processor of the charger will monitor the voltages of each cell of the battery pack and control charging current whic...

Page 16: ...you choose The value on the left of the second line of the charger is current the user sets After setting the current and voltage press the START ENTER button for more than 3 seconds to start the process This displays the number of cells you set up and the processor detects R Number of cells detected by charger S Number of cells set by you at the previous screen Start Enter Batt type Stop 3 second...

Page 17: ...more than 3 seconds to start the process This displays the number of cells you set up and the processor detects R Number of cells detected by charger S Number of cells set by you at the previous screen FAST CHARGING OF LITHIUM BATTERY Charging current will drop towards the end of charging a specific CV process is reduced to the charging process earlier In fact the charging current reach 1 5 when t...

Page 18: ... you at the previous screen If both numbers are identical you can start charging process by press START ENTER button If not press BATT TYPE STOP button to go back to previous screen to recheck the number of cells of the battery pack before going ahead STORAGE CONTROL OF LITHIUM BATTERY This function is for charging discharging batteries which are not used at once This program is designed for charg...

Page 19: ...mber of cells detected by charger S Number of cells set by you at the previous screen If both numbers are identical you can start charging process If not press BATT TYPE STOP button to go back to previous screen to recheck the number of cells of the battery pack before going ahead This screen shows the real time status of discharging you can press BATT TYPE STOP button to stop discharging DISCHARG...

Page 20: ...s ENTER START button for more than 3 seconds to start discharging This program is only suitable for charging Pb lead acid battery with nominal voltage from 2 to 20V Pb lead acid battery is a completely different from NiMH NiCD battery These batteries can only deliver current lower in comparison to their capacity The same restriction applies to the charging process consquently the optimum charge cu...

Page 21: ...can press Inc or Dec button to change the parameter value press START ENTER button to store the value The screen displays the real time charging status Press BATT TYPE STOP button to stop the process The audible sound indicate the end of process CHARGING NIMH NICD BATTERY IN THE AUTO CHARGE MODE In this program the charger detects the condition of the battery which is connected to the output and a...

Page 22: ...d indicates the end of process Re peak cycle number 1 shows on the display Press the START ENTER button to make the re peak cycle number blink and press INC or DEC button to find the desired number of times to re peak charge the battery Press the START ENTER button to confirm selection Set discharge current on the left and final voltage on the right Range of the discharge current is 0 1 5 0A range...

Page 23: ...sound alerts the end of discharging You can set up sequence on the left and the number of cycles on the right Range of the cycle number is 1 5 Press BATT TYPE STOP button to stop program you can press Inc or Dec button to alter charge current the sound indicates the end of program CHARGE DISCHARGE DISCHARGE CHARGE CYCLE OF NIMH NICD BATTERY Battery type Elapsed time Battery voltage Discharged or c...

Page 24: ... use INC or DEC to set up the parameter The example is Lipo battery pack 2S 7 4V Set the voltage and number of cells along with the normal voltage 1S 6S Set the charge current it can be adjusted UP200AC DUO 0 1 12 0A UP100AC QUAD 0 1 10 0A Set the discharge current it can be adjusted 0 1A 5 0A Set the discharge voltage it can be adjusted 3 0 3 3V Cell Start Enter 3 seconds DEC INC DEC INC DEC INC ...

Page 25: ...ndicate the saved profile This program is to load the data stored at the save data program Press the START ENTER button more than 3 seconds to load a memory otherwise you only enter to the setting mode Loading the data Start Enter 3 seconds DEC INC DEC INC TVC YOUR RISK 4 20V SAVE PROGRAM SAVE SAVE PROGRAM ENTER BATT MEMORY 1 LiPo 7 4V 2S BATT MEMORY 1 C 4 9A D 2 2A ENTER CHARGER LOAD Next flash T...

Page 26: ...charger with main battery lead and balance wires to balance socket Press the START ENTER button to enter the Lithium Battery Meter program The screen indicate each cell s voltage The screen indicate the total voltage the highest voltage and the lowest voltage Start Enter PROGRAM SELECT Li BATT METER 4 19 4 15 4 18V 0 00 0 00 0 00V MAIN 12 52V H4 190V L4 160V 25 ...

Page 27: ...he program can insert a time delay to occur after each charge and discharge process to allow the battery adequate time to cool down before being subjected to the next process The value ranges from 1 to 60 minutes When you start a charge process the integral safety time automatically starts running at the same time This is programmed to prevent overcharge the battery if it proves to be faulty or if...

Page 28: ...uttons to confirm your action The beep or melody sounded at various times during operation to alert different mode changes These audible sounds can be on or off This program monitors the voltage of input battery If the voltage drops below the value you set the operation forcibly terminated to protect the input battery This screen shows the external and internal temperature Capacity Cut Off ON 5000...

Page 29: ...ry is connected with balance lead you can check voltage of each cell in the battery pack VERSION 1 00 LOAD FACTORY SET ENTER Ext Temp 0C Int Temp 26C 4 19 4 15 4 18V 0 00 0 00 0 00V VARIOUS INFORMATION DURING THE PROCESS VARIOUS INFORMATION DURING THE PROCESS You can inquire various information on LCD screen during charging or discharging process When you press Dec button the screen will display t...

Page 30: ...pacity which the user sets The charging time is longer than the maximum charging time which the user sets The battery voltage is higher than the maximum voltage which the user sets when charging in balance mode CONNECT ERROR CHECK MAIN PORT CELL NUMBER INCORRECT CELL ERROR HIGH VOLTAGE CELL ERROR LOW VOLTAGE INT TEMP TOO HI DC IN TOO LOW DC IN TOO HIGH BATTERY WAS FULL CELL ERROR VOLTAGE INVALID E...

Page 31: ...s to material or operational defects which are present at the time of purchase During that period we will repair or replace free of service charge for products deemed defective due to those causes You will be required to produce proof of purchase invoice or receipt This warranty is not valid for any damage or subsequent damage arising as a result of misuse modification or as a result of failure to...

Page 32: ...Manufactured by Ultra Power Technology Limited www ultrapower hk E mail info ultrapower hk ...

Reviews: