SYSTEM SET UP
by 11.9, set this number as the value for
safety time setting. If the charger stopped at
this threshold, about 140% of the capacity will
have been fed into the battery.
This program sets the maximum charge
capacity that will be supplied to the battery
during charge. If the deltapack voltage is not
detected nor the safety time expired by any
reason, this feature will automatically stop the
process at the selected capacity value.
The beep sounds at every time pressing the
buttons to confirm your action. The beep or
melody sounded at various times during
operation to alert different mode changes.
These audible sounds can be on or off.
This program monitors the voltage of input
battery. If the voltage drops below the value
you set the operation forcibly terminated to
protect the input battery.
This screen shows the external and internal
temperature.
Capacity Cut-Off
ON 5000mAH
Key Beep
ON
Buzzer
ON
Capacity
Current
Safety Time
2000mAh
2.0A
(2000/2.0=1000)/11.9=84 minutes
3300mAh
3.0A
(3300/3.0=1100)/11.9=92 minutes
1000mAh
1.2A
(1000/1.2=833)/11.9=70 minutes
Input Power Low
Cut-Off 11.0V
Ext. Temp 0C
Int. Temp 37C
For example:
DEC. INC.
DEC. INC.
DEC. INC.
DEC. INC.
27