background image

2

   

WARNINGS

Ultra Pure humidifiers are advanced products, whose operation is specified in 

the technical documentation supplied with the product or can be downloaded, 

even prior to purchase, from the website www.ultrapureus.com. Each ultra 

pure product, in relation to its advanced level of technology, requires setup/

configuration/programming/commissioning to be able to operate in the 

best possible way for the specific application. The failure to complete such 

operations, which are required/indicated in the user manual, may cause the 

final product to malfunction; Ultra Pure accepts no liability in such cases. The 

customer (manufacturer, developer or installer of the final equipment) accepts 

all liability and risk relating to the configuration of the product in order to 

reach the expected results in relation to the specific final installation and/or 

equipment. Ultra Pure may, based on specific agreements, act as a consultant 

for the installation/commissioning/use of the unit, however in no case does 

it accept liability for the correct operation of the humidifier and the final 

installation if the warnings or suggestions provided in this manual or in other 

product technical documents are not heeded. In addition to observing the 

above warnings and suggestions, the following warnings must be heeded for 

the correct use of the product: 

DANGER OF ELECTRIC SHOCK: 

The humidifier contains live electrical components. 

Disconnect the mains power supply before accessing inside parts or during 

maintenance and installation.

DANGER OF WATER LEAKS:

 

 The humidifier automatically and constantly fills/drains 

certain quantities of water. Malfunctions in the connections or in the humidifier 
may cause leaks.

  

IMPORTANT

Ulltra Pure compact is a component integrated in various applications. Its

installation requires the installer inserts appropriate protections against

direct contact with parts carrying dangerous voltages . Nobody should 

have access to parts with dangerous voltage during normal operation of the 

humidifier. 

Environmental and power supply conditions must conform to the values

specified on the product rating labels. 

The product is designed exclusively to humidify rooms directly.

Only qualified personnel who are aware of the necessary precautions and

able to perform the required operations correctly may install, operate or

carry out technical service on the product. 

Only water with the characteristics indicated in this manual must be used for 

water vapor production. 

All operations on the product must be carried out according to the instructions 

provided in this manual and on the labels applied to the product. Any uses

or modifications that are not authorized by the manufacturer are considered 

improper. Ultra Pure declines all liability for any such unauthorized use. 

Do not attempt to open the humidifier in ways other than those specified

in the manual.

Observe the standards in force in the place where the humidifier is installed.

Keep the humidifier out of the reach of children and animals. 

Do not install and use the product near objects that may be damaged when 

in contact with water (or condensate). Ultra Pure declines all liability for

direct or indirect damage following water leaks from the humidifier. 

Do not use corrosive chemicals, solvents or aggressive detergents to clean

the inside and outside parts of the humidifier, unless specifically indicated

in the user manual.

Do not drop, hit or shake the humidifier, as the inside parts and the linings

may become inoperable..

Ultra Pure adopts a policy of continual development. Consequently,

Ultra Pure reserves the right to make changes and improvements to any

product described in this document without prior warning. The technical

specifications shown in the manual may be changed without prior warning. 

The liability of  Ultra Pure in relation to its products is specified in the 

Ultra Pure general contract conditions, available on the website www.

ultrapureus.com and/or by specific agreements with customers; specifically, 

to the extent where allowed by applicable legislation, in no case will Ultra

Pure, its employees or subsidiaries be liable for any lost earnings or sales,

losses of data and information, costs of replacement goods or services,

damage to things or people, downtime or any direct, indirect, incidental,

actual, punitive, exemplary, special or consequential damage of any kind

whatsoever, whether contractual, extra-contractual or due to negligence, or 

any other liabilities deriving from the installation, use or impossibility to use 

the product, even if Ultra Pure or its subsidiaries are warned of the possibility 
of such damage.

WARRANTY ON MATERIALS: 2 YEARS.  WARRANTY PERIOD STARTS NO 

LATER THEN 90 DAYS FROM DELIVERY OF EQUIPMENT AND NOT 

WHEN EQUIPMENT IS STARTED

DI WATER IS ESSENTAIL FOR PROPER OPERATION. ANY OTHER FORM

 OF WATER VOIDS WARRANTY. ULTRA PURE TAKES NO 

RESPONSIBILITY TO ANY FOREIGN DEBREE IN AIR OR INSIDE 

ULTRA SONIC HUMIDIFIER DUE TO HARDNESS OF WATER OR ANY

 CONTAMINENTS IN WATER SUPPLY. 

Summary of Contents for pureMist

Page 1: ...NO POWER SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT Engineering Manual Compact Ultrasonic Humidifier...

Page 2: ...r with the characteristics indicated in this manual must be used for water vapor production Alloperationsontheproductmustbecarriedoutaccordingtotheinstructions provided in this manual and on the label...

Page 3: ...2 Meaning of the symbols 12 6 3 Keypad 12 6 4 Main display 12 6 5 Display software release 12 7 CONFIGURATION PARAMETERS 13 7 1 Basic parameters 13 7 2 Advanced parameters 13 8 ALARMS 14 9 MAINTENANC...

Page 4: ...essories Wand Distributor Production Supply Temperature Electrical Rating Amp Max Weight Dimensions 1 1 2 2 Lbs Hr 33 8 104 F 115 V 60Hz 8 MFS 15 28lbs 12 x 9 x 11 Temp Hum Stat Diffuser Remote Displa...

Page 5: ...fier The following are contained inside fig 1 A IOM manual B Optional accessories if purchased ie distributor 50M filter plastic tube seperate box S S distributer seperate box 10 1 4 RED inlet water 3...

Page 6: ...3 8 push connect fitting Black Connect included RJ11 cord to display and plug into cabinet Terminate 3 wire color coded wired if optional temperature and humidity sensor is used to side of cabinet col...

Page 7: ...tially chemically or bacteriologically contaminated water is prohibited 2 2 Drain water Drain water from the humidifer is not toxic and can be drained into the approved drain system Attach 1 2 FPT fem...

Page 8: ...e elbow It s necessary to clean the filter with compressed air or running water periodically frequency depends on the environment in which the system is installed Features filter 50 micron H 5 D 2 3 6...

Page 9: ...ansducer management only for 2 transducer version OFF parallel management modulation of all 2 ON if demand is less than 50 it works only one transducer at a time alternately Tab 4 c 4 2 Power cable co...

Page 10: ...umper inputs M14 1 and M14 2 enable on the main board connect terminals M10 1 and M10 2 to a humidistat or a remote switch voltage free contact set parameter A0 0 to enable On Off operation see Chap 7...

Page 11: ...emptied automatically When in standby the fan stays on for 5 min 5 3 Autotest When humidifier is first started from off if enabled and humidity production is required a test cycle is run A complete f...

Page 12: ...set the values ENTER PRG for 2 seconds access the list of parameters inside the list of parameters select and confirm like Enter on a computer keyboard 6 4 Display software release 1 on power up the d...

Page 13: ...Maximum time to measure high level s 1 60 10 AE Restart fan time in standby for integrated probe reading min 0 120 10 AF Piezoelectric transducer working life h 0 9999 9999 with demineralised water b...

Page 14: ...ity probe signal cable yes humidification interrupted AUTO 3 slow flashes H_ Low humidity The signal from the probe indi cates humidity less than 20 rH Check humidity probe signal cable yes humidifica...

Page 15: ...iew the inside of the tank Scale build up on the surface of the piezoelectric transducers Clean the inside of the tank and replace the transducers Tab 8 b These malfunctions can be avoided by carrying...

Page 16: ...cally to remove it 4 clean or replace the transducers by removing the screws see Fig 9 b after replacement test water tightness by filling the tank manually 5 reconnect the transducer power cables 6 r...

Page 17: ...17 10 GENERAL FEATURES AND MODELS 10 4 Version 115V Fig 10 c...

Page 18: ...ity at 20 C 0 50 S cm total hardness 0 25 mg l CaCO3 temporary hardness 0 15 mg l CaCO3 total quantity of dissolved solids cR depending on specific conductivity 1 dry residue at 180 C depending on spe...

Page 19: ...Inactivity time for washing on next start R W 32 159 Parameter b3 Washing time fill drain R W 33 160 Parameter b4 Start delay time R W 34 161 Parameter b5 Operating hours for CL alarm R W 35 162 Param...

Page 20: ...at 1 the humidifier excludes the external command signals external regulator or probes and uses the value of Integer 60 modbus 188 as like comand signal The humidity production can be managed in two...

Page 21: ...of a signal Y from an external device The type of signal can be selected between the following standards 0 to 10 Vdc 2 to 10 Vdc 0 to 20 mA 4 to 20 mA Maximum humidifier production corresponding to th...

Page 22: ...ituation is repeated alarm EP is activated which shuts down the unit If after a percentage of A8 set by parameter Ab default 70 the water is above the high level threshold atomised water production st...

Page 23: ...llowing fields Percentage request sent to the Master Fig 3 Operating hour counter Fig 4 resettable pressing UP DOWN for 5 seconds see parameter d3 Unit alarms Fig 5 means no alarms are present resetta...

Page 24: ...ctrical wiring from alarm relay output on the master to auxiliary input J17 on the slave and vice versa from alarm relay output on the slave to auxiliary input J17 on the master Main board Slave unit...

Page 25: ...Main Board Connections MASTER UNIT Connections M 11 TX RX GND GND 1 RS485 Supervisore ON OFF 4 Main Board Connections SLAVE UNIT Connections 2 3 6 4 7 5 1 8 ON M9 M 11 M 11 M 11 6 6 6 TLan 2 Supervis...

Page 26: ...Ultra Pure Systems 1855 E Southern Ave Mesa AZ 85204 800 729 5192 www ultrapureus com...

Reviews: