background image

PIN-1 YELLOW   Starter Output-

This wire will test 0V when the key is off, in the Accessory position and when 

the Ignition is in the on position. The starter wire is 12volts during the start/ crank position only.

PIN-2 GREEN      Heater/Acc Output-

This wire will test 0V when key is off, 12volts in the ACC and iIGN 

positions and off during start/ crank position.

PIN-3 RED           12volt Input(30amp)- 

This input supplies the 12volt power for the Ignition, Park Lights  and 

the Selectable outputs. 

PIN-4 RED           12volt Input(30amp)- 

This input supplies the 12volt power for the Accessory and Starter 

outputs. 

PIN-5 BLUE         Ignition Output- 

This wire will test 0V in the off and Accessory positions the switch to12volts 

in the Ignition and Start positions.

PIN-6 WHITE       Selectable Output - 

2nd Ignition, Accessory or Start output. Programmable. (See Page 21).

Note: This output does not switch to default when the system is reset. 

PIN-1 BROWN           (+) Siren / (-) Horn (Programmable)- 

Connect this wire to the Brown or Red wire on the 

SIREN (Alarm Models) This output can be programmed to act as an additional HORN output (+)

PIN-2 ORANGE         Starter Kill/ Anti-Grind- 

This wire can be connected to an additional relay to disable the 

start circuit when the lock button is pressed. The output will also stay on when remote started, this will prevent 
the starter motor from being re-engaged while the vehicle is running.

PIN-3 WHITE             Jumper Selectable Park Light Output (+ or -)- 

Connect to the vehicles positive park light 

wire or change the jumper and connect to the vehicle negative park light wire. The default position of the jumper 
is 

Positive Park light Output.

PIN-4  BLACK

           

System Ground Input- 

Connect to chassis ground.

PIN 1- GREEN Wire- Negative Lock Output

Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**

 

PIN 2- 12volt Output for Door Lock Module

This output will supply 12volts for a plug-in type door lock module. Do not use this input to power-up relays 
**LOW CURRENT ONLY**

PIN 3- BLUE Wire- Negative Unlock Output

Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**

***SEE PAGE 24 FOR RELAY DIAGRAMS***

 

  4-PIN CONNECTOR

  4 PIN AUXILIARY SENSOR CONNECTOR

FOR MORE DETAILED INFORMATION ON PROGRAMMING, WIRING DIAGRAMS, DOOR LOCK 

CONFIGURATION AND OTHER INFORMATION, PLEASE VISIT

WWW.ULTRASTARTERS.COM/DIAGRAMS

PAGE 11

95 SERIES

  SYSTEM WIRING DETAILS

SYSTEM PROGRAMMING - 

Menu 1

INSTALL MANUAL

SYSTEM PROGRAMMING - 

Menu 1

PAGE 10

95 SERIES

INSTALL  MANUAL

  SYSTEM WIRING DETAILS

WHITE

SYSTEM GROUND INPUT

JUMPER SELECTABLE PARK LIGHT OUTPUT (+ OR -)

(+) SIREN/  HORN OUTPUT (-)  

STARTER-KILL/ ANTI-GRIND OUTPUT

BLACK

ORANGE

BROWN

BLUE

OUTPUT TO ACTIVATE IGNITION CIRCUIT

WHITE*

SELECTABLE OUTPUT (DEFAULT SECOND IGNITION)

RED

30A HIGH CURRENT 12VOLT INPUT

YELLOW

OUTPUT TO ACTIVATE START CIRCUIT 

RED

30A HIGH CURRENT 12VOLT INPUT 

GREEN

OUTPUT TO ACTIVATE ACCESSORY/ HEATER CIRCUIT

BLUE

NEGATIVE OUTPUT FOR UNLOCK

 

12+ OUTPUT FOR DOOR LOCK MODULE 

GREEN

NEGATIVE OUTPUT FOR UNLOCK

 

  

 6-PIN CONNECTOR

INSTALL  MANUAL

Summary of Contents for 3295 SERIES

Page 1: ... ultrastarters com THIS MANUAL COVERS THE OPERATIONS OF THE 3295 4295 SERIES REMOTE STARTERS AND ALARMS WARNING NEVER USE AN AUTOMATIC TRANSMISSION STARTER IN A MANUAL TRANSMISSION VEHICLE 95 SERIES AdvancedRemoteStarters VehicleSecuritySystems ...

Page 2: ... Connector Views Wiring Description PROGRAM MENUS 15 23 Program Menu 1 Detailed Program Menu 2 Detailed Program Menu 3 Detailed Program Menu 4 Detailed DOOR LOCK DIAGRAMS 24 25 Relay Diagrams SHOCK SENSOR ALARM MODELS 26 Entering Adjustment Mode Shock Sensor Adjustment QUICK VIEW OPERATIONS CHART 27 Basic Operations Service Mode Emergency Override TRANSMITTER PROGRAMMING 28 Adding Reprogramming Tr...

Page 3: ...TACH DETECTION INPUT CONNECT TO COIL INJECTOR BRAKE SWITCH INPUT 12VOLT WHEN BRAKE IS PRESSED HOOD PIN SWITCH GROUND WHEN HOOD IS OPENED PARK BRAKE INPUT M SERIES ONLY NEGATIVE DOOR INPUT WHEN DOOR OPENED Status LEDs Program Button The selectable output can be changed in the program mode to output as a 2nd Accessory or 2nd Start output Default output is second ignition This output does not change ...

Page 4: ... to the data port to set the default to Fortin bypass module 1 2 3 4 SELECTABLE PARK LIGHT OUTPUT GROUND OUTPUT FOR ADDITIONAL SENSOR FULL TRIGGER FOR ALARM MODELS PRE WARN TRIGGER FOR ALARM MODELS OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT OUTPUT FOR VOLTAGE INVERTER 12VOLT OUTPUT FOR BYPASS MODULE GROUND OUTPUT FOR BYPASS MODULE WHILE RUNNING OUTPUT BYPASS TURN O...

Page 5: ...ES USING THE DATA TO DATA TYPE CONNECTION THERE ARE 2 SELECTION TYPES THE DEFAULT SETTING IS FOR IDATALINK MODULES THE SECOND IS FOR FORTIN BYPASS MODULES IF THE BYPASS KIT IS A IDATA PRODUCT SIMPLY CONNECT TO THIS INPUT AND PROGRAM THE BYPASS MODULE AS PER THE INSTRUCTIONS WHEN INSTALLING A FORTIN BYPASS MODULES POWER UP THE STARTER ALARM WITH THE FORTIN MODULE ALREADY CONNECTED TO THE DATA PORT ...

Page 6: ...RAMMING 1 Cycle the Ignition Key On Off On Off On Leaving the key ON 2 Press and HOLD the Program Switch The Horn Siren will chirp 1 time CONTINUE to HOLD If the Horn Siren does not chirp turn the key off then repeat step 1 3 Continue to HOLD the Program Switch and the Horn Siren will chirp 5 times 4 Press the LOCK BUTTON on each of the remote s to be programmed Pause for about 1 second between pr...

Page 7: ...TPUT UNLOCK STATUS WITH DISARM PASSIVE DOOR LOCKS PASSIVE DOOR LOCKS DISABLED PASSIVE DOOR LOCKS ENABLED 8 PASSIVE ARMING PASSIVE ST KILL FULL PASSIVE ARMING ENABLED PASSIVE SAFETY REARM ENABLED 9 ALARM SHOCK AUX SENSOR INTERNAL SHOCK DISABLED AUX SENSOR DISABLED BOTH SENSORS ENABLED ACTIVE ARMING ONLY PROGRAM MODE 1 SETTING LED FLASHES SETTING DESCRIPTION OPTION 1 1 CHIRP OPTION 2 2 CHIRPS OPTION...

Page 8: ...M MODE 3 PROGRAM MODE 4 PROGRAM MODE 3 see page 21 for detailed instructions PROGRAM MODE 4 see page 23 for detailed instructions SYSTEM PROGRAMMING Menu 1 SYSTEM PROGRAMMING Menu 1 AUTO TACH TACHLESS SETTING LED FLASHES SETTING DESCRIPTION OPTION 1 1 CHIRP OPTION 2 2 CHIRPS OPTION 3 3 CHIRPS 1 2 3 4 TACH OPTIONS HYBRID MODE 1 ADJUST FOR OVER CRANK INCREASES TACH SETTING BY 10 ADJUST FOR UNDER CRA...

Page 9: ... proper Tach signal has been programmed the system will chirp the Horn Siren and flash the park lights two times If the tach wire is not connected the park lights will flash and the horn will chirp 4 times to indicate Tachless Mode If the Tach is not learned when the start button is pressed the park lights will flash 7 times The system must be Tach Learned before remote starting If Tach does not l...

Page 10: ... WIRING DETAILS WHITE SYSTEM GROUND INPUT JUMPER SELECTABLE PARK LIGHT OUTPUT OR SIREN HORN OUTPUT STARTER KILL ANTI GRIND OUTPUT BLACK ORANGE BROWN BLUE OUTPUT TO ACTIVATE IGNITION CIRCUIT WHITE SELECTABLE OUTPUT DEFAULT SECOND IGNITION RED 30A HIGH CURRENT 12VOLT INPUT YELLOW OUTPUT TO ACTIVATE START CIRCUIT RED 30A HIGH CURRENT 12VOLT INPUT GREEN OUTPUT TO ACTIVATE ACCESSORY HEATER CIRCUIT BLUE...

Page 11: ...larm Models This output can be programmed to act as an additional HORN output PIN 2 ORANGE Starter Kill Anti Grind This wire can be connected to an additional relay to disable the start circuit when the lock button is pressed The output will also stay on when remote started this will prevent the starter motor from being re engaged while the vehicle is running PIN 3 WHITE Jumper Selectable Park Lig...

Page 12: ...OUTPUT FOR TRUNK RELEASEACTIVATION NEGATIVEACCESSORYOUTPUT AUXILIARYOUTPUT 2 AUXILIARYOUTPUT 1 PROGRAMMABLE OUTPUT BRAKE SWITCH INPUT WHEN BRAKE IS PRESSED HOOD PIN SWITCH INPUT TACH WIRE INPUT WAIT TO START DIESELVEHICLES POSITIVE DOOR PIN INPUT ALARMSAND MANUALONLY NEGATIVE DOOR PIN INPUT ALARMSAND MANUALONLY FOR MORE DETAILED INFORMATION ON PROGRAMMING WIRING DIAGRAMS DOOR LOCK CONFIGURATION AN...

Page 13: ...e switch that changes to 12volts when the brake is pressed Connect to door pin for Passive Arming on the 3295 8 BLACK WHT N A 9 GREEN WHT Hood Pin Input Connect this wire to the supplied hood pin switch If ground is detected on this input the remote starter will not activate 10 BLUE WHT Tach Wire Input A C This wire is used to to detect when the vehicle has started The Tach source is typically tak...

Page 14: ...nnect this wire to the your bypass modules negative turn on wire When the remote starter is activated this wire will switch to ground 2 BLACK Wire System Ground Connect this wire to the ground input on the bypass module 3 RED Wire 12volt Power Input Connect this wire the 12volt input on the bypass module 3 PIN BYPASS CONNECTOR SYSTEM CHASSIS GROUND INPUT RED CONSTANT 12 VOLT INPUT 20AMP BLACK WHIT...

Page 15: ...TTER PROGRAMMING 1 Cycle the Ignition Key On Off On Off On Leaving the key ON 2 Press and HOLD the Program Switch The HORN SIREN will chirp 1 time CONTINUE to HOLD If the HORN SIREN does not chirp turn the key off then repeat step 1 3 Continue to HOLD the Program Switch and the HORN SIREN will chirp 5 times 4 Press the LOCK BUTTON on each of remote s to be programmed Pause for about 1 second betwe...

Page 16: ...tem will provide 2 unlock pulses w unlock and 1 lock pulse w lock 1 CHIRP SETS OPTION 2 DOUBLE LOCK SINGLE UNLOCK PULSE The system will provide 2 lock pulses and 2 unlock pulses CHANGE SETTING 2 GOTO SETTING 3 PRESS RELEASE THE VALET SWITCH PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S CHANGE SETTING 3 GOTO SETTING 4 PRESS RELEASE THE VALET SWITCH PRESS HOLD THE VALET SWITCH UNTIL THE SIREN ...

Page 17: ...TTING 5 IS SELECTED 5 CHIRP PRESS 1 TIME 5X 1 CHIRP 2 CHIRP 3 CHIRP CHANGE SETTING 6 GOTO SETTING 7 PRESS RELEASE THE VALET SWITCH PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 6 AUXILIARY CHANNEL 2 THE SIREN WILL CHIRP 6 TIMES WHEN SETTING 6 IS SELECTED 6 CHIRP PRESS 1 TIME 6X 1 CHIRP 2 CHIRP 3 CHIRP SETS OPTION 1 NEGATIVE IGNITION OUTPUT Output acts as a negative ignition output Ac...

Page 18: ...d SETS OPTION 3 PASSIVE ARMING DISABLED The alarm will not automatically Must be armed by the remote DEFAULT SETS OPTION 1 INTERNAL DISABLED The Internal Sensor input will be Active not be monitored when the alarm is armed SETS OPTION 2 AUX DISABLED The Auxiliary Sensor input will be Active not be monitored when the alarm is armed ALARM MODELS ONLY 1 CHIRP 2 CHIRP CHANGE SETTING 7 GOTO SETTING 8 P...

Page 19: ... CON T ON NEXT PAGE SETS OPTION 1 30 SECOND The park light output will flash for all functions and will stay active for 30 seconds when unlock is pressed SETS OPTION 2 NORMAL OPERATION The park lights will flash for all functions DEFAULT SETS OPTION 1 SECURE The LED Program Switch must be held for 15 seconds to place the system into Valet Mode SETS OPTION 2 STANDARD The LED Program Switch must be ...

Page 20: ...CHIRP SETS OPTION 1 TYPE 2 The doors will unlock before remote start lock when remote starter starts and again when the remote start shuts down SETS OPTION 2 RE LOCK The doors will automatically lock when the remote starter shuts down SETS OPTION 3 NORMAL OPERATION No additional door lock or door unlock pulses DEFAULT ENTERING PROGRAM MODE 3 CHANGE SETTING 1 GOTO SETTING 2 PRESS RELEASE THE VALET ...

Page 21: ...H PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 4 RE ARM OPTIONS THE SIREN WILL CHIRP 4 TIMES WHEN SETTING 4 IS SELECTED 4 CHIRP PRESS 1 TIME 4X 1 CHIRP 2 CHIRP 3 CHIRP SETS OPTION 1 TYPE 2 The rearm output pulses only when the lock button is pressed SETS OPTION 2 AFTER START The re arm output will pulse after the remote start starts the vehicle DEFROST HEATED SEAT SETS OPTION 3 REAR...

Page 22: ...OLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 7 LED FLASHES THE SIREN WILL CHIRP 7 TIMES WHEN SETTING 7 IS SELECTED 7 CHIRP PRESS 1 TIME 7X 1 CHIRP 2 CHIRP SYSTEM PROGRAMMING Menu 1 ENTERING PROGRAM MODE 4 ON OFF ON OFF ON Leaving the key ON IGNITION KEY PROGRAM SWITCH 1 CHIRP Confirming Program Mode SIREN CHIRP REMOTE BUTTON Press Status Button to Select Menu 4 Press and release 1 time SET...

Page 23: ...GOTO SETTING 5 PRESS RELEASE THE VALET SWITCH PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 4 TACH WAIT THE SIREN WILL CHIRP 4 TIMES WHEN SETTING 4 IS SELECTED 4 CHIRP PRESS 1 TIME 4X 1 CHIRP 2 CHIRP 3 CHIRP 1 CHIRP CHANGE SETTING 3 GOTO SETTING 4 PRESS RELEASE THE VALET SWITCH PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 3 ADJUST FOR OVER CRANK THE SIREN WILL CHIRP 3 ...

Page 24: ...lay Blue NEGATIVE DOOR LOCK LOW CURRENT Ground Ground 12volts 12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v Relay POSITIVE DOOR LOCK LOW CURRENT 12volts 12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green POSITIVE TYPE USING INVERTER Alarm and or Starter Module Do...

Page 25: ...Switch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue Green 87 86 85 87a 30 87 86 85 87a 30 x x x x USE SPDT 12v Relay AFTER MARKET DOOR LOCK ACTUATORS 12volts 12volts Alarm and or Starter Module Door lock Output Blue Green 87 86 85 87a 30 87 86 85 87a 30 Ground Ground FOR MORE DETAILED INFORMATION ON PROGRAMMING WIRING DIAGRA...

Page 26: ...T LEAST SENSITIVE SETTING IS SEN 1 THE SHOCK SENSOR SENSITIVITY IS SET USING THE REMOTE PROGRAM MODE FEATURE ALARM MODELS ONLY PRESS AND RELEASE THE START BUTTON TO INCREASE THE SENSITIVITY THE LCD WILL SHOW THE CURRENT SETTING THE HIGHEST MOST SENSITIVE SETTING IS SEN 10 PRESS AND RELEASE THE STATUS BUTTON ON THE REMOTE TO EXIT ENTER REMOTE PROGRAM MODE ADJUSTING THE SENSOR SENSITIVITY EXIT PROGR...

Page 27: ...S INJURY this remote start system must be set into Service Mode before any under hood servicing is started Service Mode will prevent the vehicle from starting while the vehicle is being serviced It is the sole responsibility of the vehicle s owner to place the system into Service Mode The manufacture accepts no responsibility for accidental starting of the vehicle while the vehicle is being servic...

Page 28: ...ITION KEY ON OFF ON OFF ON LEAVE THE KEY ON ENTERING TRANSMITTER PROGRAM MODE PRESS AND HOLD THE PROGRAM SWITCH THE PARK LIGHTS WILL TURN ON AND THE HORN WILL CHIRP 1 TIME CONTINUE TO HOLD THE PROGRAM SWITCH 1 CHIRP CONFIRMS ENTERING PROGRAM MODE 5 CHIRPS CONFIRMS TRANSMITTER PROGRAM MODE PRESS AND RELEASE THE LOCK BUTTON ON EACH ON THE REMOTE S TO BE PROGRAMMED THE PARK LIGHTS WILL FLASH AND THE ...

Page 29: ... ISSUE ULTRA FAULT 1 ULTRA BRAKE 1 TOGGLE HOOD FAULT THIS FAULT WOULD OCCUR IF THE HOOD WAS OPENED OR THE HOOD SWITCH IS BROKE OR OUT OF ALIGNMENT ULTRA FAULT 1 ULTRA HOOD 1 TOGGLE TACH FAULT THIS FAULT WOULD OCCUR IF THE VEHICLE HAD A START ISSUE SUCH AS A DEFECTIVE BYPASS MODULE ULTRA FAULT 1 ULTRA TACH 1 TOGGLE VALET FAULT THIS FAULT WOULD OCCUR IF THE SYSTEM WAS IN VALET AND YOU PRESSED START ...

Page 30: ...ND THE TRIGGER ULTRA ALARM 1 ULTRA DOOR 1 ULTRA ALARM 1 ULTRA SHOCK 1 ULTRA ALARM 1 ULTRA HOOD 1 ULTRA ALARM 1 ULTRA AUX 1 ULTRA ALARM 1 ULTRA PANIC 1 TOGGLE TOGGLE TOGGLE TOGGLE TOGGLE SHOCK TRIGGER THIS PAGE WOULD OCCUR IF THE VEHICLE WAS IMPACTED HARD ENOUGH TO TRIGGER THE SHOCK SENSOR HOOD TRIGGER THIS PAGE WOULD OCCUR IF A HOOD WAS OPENED ON THE VEHICLE AUX TRIGGER THIS PAGE WOULD OCCUR IF TH...

Page 31: ...s and the HORN optional will honk the same number of times as the events in memory Maximum four events four honks NOTE If the HORN does not honk there are no events in memory Step 3 Press the Program Button once to view the last shut down code The HORN optional will honk once to confirm code one If the HORN does not honk there are no codes in memory Step 4 The LEDs on the antenna will flash a code...

Page 32: ...thorized dealer but have been registered please fill out the service request form at http www ultrastarters com wiring_diagrams html PRODUCT INFORMATION www ultrastarters com TECHNICAL SUPPORT support ultrastarters com ORDERING orders ultrastarters com APPLICATED SECURITY TECHNOLOGIES INC UNIT 2 8334 FOOTHILL BLVD SUNLAND CA 91040 USA PAGE 32 95SERIES INSTALL MANUAL ...

Reviews: