SYSTEM PROGRAMMING -
Menu 1
PAGE 30
95 SERIES
INSTALL MANUAL
ALARM TRIGGERS
DOOR TRIGGER
THIS PAGE WOULD OCCUR IF
A DOOR WAS OPENED ON THE
VEHICLE.
ALARM TRIGGERS & PAGER MODE
WHEN THE ALARM IS TRIGGERED THE SYSTEM WILL PAGE THE REMOTE WITH THE
SPECIFIC ALARM TRIGGER. THE REMOTE WILL START TO BEEP AND THE LCD WILL
ALTERNATE BETWEEN “ALARM” AND THE “TRIGGER”
UL
TRA
ALARM
1
UL
TRA
DOOR
1
UL
TRA
ALARM
1
UL
TRA
SHOCK
1
UL
TRA
ALARM
1
UL
TRA
HOOD
1
UL
TRA
ALARM
1
UL
TRA
AUX
1
UL
TRA
ALARM
1
UL
TRA
PANIC
1
TOGGLE
TOGGLE
TOGGLE
TOGGLE
TOGGLE
SHOCK TRIGGER
THIS PAGE WOULD OCCUR IF
THE VEHICLE WAS IMPACTED
HARD ENOUGH TO TRIGGER
THE SHOCK SENSOR.
HOOD TRIGGER
THIS PAGE WOULD OCCUR IF
A HOOD WAS OPENED ON THE
VEHICLE.
AUX TRIGGER
THIS PAGE WOULD OCCUR IF
THE AUXILIARY SENSOR
INPUT IS TRIGGERED.
PANIC TRIGGER
THIS PAGE WOULD OCCUR IF
THE SYSTEM WAS SET INTO
PANIC MODE. (LOCK HELD
FOR 3 SECONDS).
DIAGNOSTICS CHART
TO ENTER DIAGNOSTIC MEMORY
If the remote starter does not activate when the start button is pressed the park lights will flash
a diagnostic to indicate what shutdown input has been triggered. For example:
If the start
button is pressed the park lights flash 3 times slowly.
Looking at the chart below this would
indicate that the system is in Service Mode, simply follow the instructions listed in the owners
manual on exiting Service Mode and the remote starter will begin to function as normal.
PARK LIGHTS
STATUS LED
DIAGNOSTIC CODE
3 Slow Flashes
LEDs “ON” Solid
System Is In Service Mode
5 Flashes
Series of 5 Flashes
Hood Open
5 Slow Flashes
Series of 5 Flashes
Ignition On During Start Attempt
6 Flashes
Series of 6 Flashes
Brake Pedal Shutdown
7 Flashes
Series of 7 Flashes
Tach Lock-Out
8 Flashes
Series of 8 Flashes 3 Start Attempts Without Starting
Step 1-
Turn the ignition ON then OFF. Press and release the Program Button.
Step 2-
The system will respond with three park light flashes and the HORN (optional) will honk the same
number of times as the events in memory.
****
Maximum four events, four honks****
NOTE:
If the HORN does not honk, there are no events in memory.
Step 3-
Press the Program Button once to view the last shut down code. The HORN (optional)will honk
once to confirm code one.
****
If the HORN does not honk, there are no codes in memory.****
Step 4-
The LEDs on the antenna will flash a code corresponding to a shut down trigger. Press the
Program Button again for the second code.
***
The HORN will honk twice to confirm code two three time for code three...***
Step 5-
To
Clear Diagnostic Memory.
While in Diagnostic Mode press and hold the
Program Button for five seconds. The park lights will flash and the HORN (optional)
will honk once.
****
Once diagnostic memory has 4 shutdown events in memory, the system will not record any further
shutdown events until the system memory has been cleared.****
LED Flashes Diagnostic
5 Flashes The system was shutdown by the brake switch input
6 Flashes The system was shutdown by the hood pin input
7 Flashes The system did not detect the Tach signal.
8 Flashes The system made 3 start attempts without starting
SYSTEM PROGRAMMING -
Menu 1
PAGE 31
95 SERIES
INSTALL MANUAL
DIAGNOSTICS