SYSTEM PROGRAMMING -
Menu 1
PAGE 4
95 SERIES
INSTALL MANUAL
QUICK VIEW WIRE DIAGRAM
1
2
3
1
2
3
1
2
3
4
THERMISTOR/ INPUT TRIGGER TO START****
The thermistor can be installed in the engine compartment for engine temperature or in
under the dash for interior temperature.
Position 1 or Position 2
BLACK**
GREEN**
BLUE**
GREEN
BLUE
N/A*
RED
BLACK
WHT/VIOLET
RED**
BYPASS MODULE DATA COMMUNICATION PORT***
*The default setting is for idatalink modules. For Fortin bypass modules power-
up the system with the Fortin module connected to the data port to set the default
to Fortin bypass module.
1
2
3
4
SELECTABLE PARK LIGHT OUTPUT*****
GROUND OUTPUT FOR ADDITIONAL SENSOR (-)
FULL TRIGGER FOR ALARM MODELS (-)
PRE-WARN TRIGGER FOR ALARM MODELS (-)
OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT (-)
OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT (-)
OUTPUT FOR VOLTAGE INVERTER*
12VOLT OUTPUT FOR BYPASS MODULE
GROUND OUTPUT FOR BYPASS MODULE
(-) WHILE RUNNING OUTPUT (BYPASS TURN ON)
12VOLT OUTPUT FOR ADDITIONAL SENSORS (+)
BY DEFAULT THE SYSTEM COMES WITH
THE PARK LIGHT JUMPER SET FOR
POSITIVE PARK LIGHT OUTPUT. TO
CHANGE THE SYSTEM TO A NEGATIVE
PARK LIGHT OUTPUT, PLACE THE JUMPER
IN THE NEGATIVE PARK LIGHT POSITION
SHOWN IN THE DIAGRAM.
(Position 2)
POSITIVE
PARK LIGHT
NEGATIVE
PARK LIGHT
SYSTEM PROGRAMMING -
Menu 1
PAGE 5
95 SERIES
INSTALL MANUAL
NOTES
PLEASE NOTE
* THE CENTRE PIN OF THE KEYLESS CONNECTOR IS LOW CURRENT AND IS
DESIGNED TO SUPPLY POWER TO DOOR LOCK MODULES (DO NOT CONNECT TO
RELAYS) OVERLOADING THIS OUTPUT WILL DAMAGE THE MODULE!
**THIS CONNECTOR IS USED FOR ALARM MODELS ONLY. A GROUND PULSE TO THE
BLUE WIRE WILL CAUSE THE ALARM TO BEEP 3 TIMES. A GROUND PULSE TO THE
GREEN WIRE WILL CAUSE THE ALARM TO ACTIVE FOR 60 SECONDS. THIS INPUT CAN
BE USED FOR AN ADDITION SENSOR SUCK AS A RADAR, GLASS BREAK OR AN
EXTRA SHOCK SENSOR. THIS INPUT IS TURNED ON AND OFF WITH THE MAIN SHOCK
SENSOR.
***THIS INPUT IS USED TO CONNECT BYPASS MODULES USING THE DATA TO DATA
TYPE CONNECTION. THERE ARE 2 SELECTION TYPES. THE DEFAULT SETTING IS FOR
IDATALINK MODULES. THE SECOND IS FOR FORTIN BYPASS MODULES. IF THE
BYPASS KIT IS A IDATA PRODUCT SIMPLY CONNECT TO THIS INPUT AND PROGRAM
THE BYPASS MODULE AS PER THE INSTRUCTIONS. WHEN INSTALLING A FORTIN
BYPASS MODULES POWER-UP THE STARTER/ALARM WITH THE FORTIN MODULE
ALREADY CONNECTED TO THE DATA PORT THEN PROGRAM AS PER THE
INSTRUCTIONS.
****THE THERMISTOR WILL DETECT THE ENGINE OR INTERIOR TEMPERATURE OF
THE VEHICLE. THIS INFORMATION WILL THEN BE DISPLAYED ON THE REMOTE
TRANSMITTER EACH TIME A FUNCTION OR STATUS CHECK IS PREFORMED. THE
TEMPERATURE CAN BE DISPLAYED IN CELSIUS OR FAHRENHEIT.
*****ALWAY TEST AND CONFIRM THE PARK LIGHT POLARITY BEFORE MAKING YOUR
CONNECTION TO THE VEHICLE.
DO NOT INSTALL THIS REMOTE STARTER INTO A
MANUAL TRANSMISSION VEHICLE!