background image

Maintenance: 

CAUTION

: Turn off and unplug unit from power before any maintenance is 

performed.  

GENERAL INFORMATION: 

The cellulous media used in these portable evaporative coolers must be kept in 
good condition to maintain the stated cooling capabilities. We recommend draining 
the unit weekly and refilling to keep water fresh and reduce mineral build-up on 
media. 

Weekly

 

Draining

 

(Accomplish when water level is low or unit is out of 
water.) 

1.  Turn unit off. Unplug and move it to an area that 

will not be damaged by water. 

2.  Unscrew the drain cap from the bottom of the 

back of the unit. Allow any remaining water to 
drain out of unit. 

3.  When cleaning the media pad, try to preserve 

the integrity of the fluted surface. 

4.  Reinstall drain cap and refill with fresh water. 

Plug in and operate per instructions. 

Regular Servicing: 

(Accomplish at least twice a season, more often in 
areas with hard water.) 
1.  Remove media frame section by extracting one 

screw from center of upper grate. 

2.  Using a water hose, wash out back with fresh 

water. Clean media pad. DO NOT use chemicals 
or pressure washer on media.

 

3.  Using a screw driver or other tool, pry off the four 

keeper discs, then push the stems back through 
the media and extract them through the back. 
Remove pad.

 

4.  Rinse media with water. Light scrubbing may be 

necessary. Be careful not to damage the media.  

NOTE:

 Average life expectancy of the rigid media 

pad is 2 years, though water with high mineral content 
will deteriorate the integrity of the media sooner. 

 

 

STEM

KEEPER 

DISC

Summary of Contents for CP35

Page 1: ...vaporative cooling is an economical way to cool and is highly effective in arid climates Air is cooled while being drawn across wet evaporative media The movement of this fresh cooled air over the skin is what makes it feel cool In order for evaporative coolers to be effective in an enclosed area a fresh air source and adequate exhaust need to be present These coolers will not work well without an...

Page 2: ... service facility for examination and or repair 6 Do Not run cord under carpeting Do Not cover cord with throw rugs runners or similar coverings Do Not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device Assembly Remov...

Page 3: ... faster cooling effect NOTE This unit can be used as a fan only or an evaporative cooler If no evaporative cooling is desired simply do not engage the pump and use only the fan feature For Evaporative Cooling With the unit already filled and turned on 1 Press the PUMP button This will activate the pump to begin saturating the media The two Droplet icons will alternately flash 2 Press the SPEED but...

Page 4: ...MER button again NOTE If continuous operation is desired Press TIMER and set at 0 0 The fan will run continuously The pump will not operate if there is no water in the unit Low Water Indication 1 When the water tank has been depleted to a certain level a red LOW WATER icon will display on the Control Panel The pump will stop operating and an audible beeping will sound for 60 seconds or until the P...

Page 5: ...dia pad try to preserve the integrity of the fluted surface 4 Reinstall drain cap and refill with fresh water Plug in and operate per instructions Regular Servicing Accomplish at least twice a season more often in areas with hard water 1 Remove media frame section by extracting one screw from center of upper grate 2 Using a water hose wash out back with fresh water Clean media pad DO NOT use chemi...

Page 6: ...it is fully drained of water 2 Carefully inspect media to verify media is not crushed broken and clogged or heavily encrusted with minerals If so dispose and replace media pad 3 Clean interior with clean water Wipe down outside with clean damp cloth 4 Store in safe dry place Do not store with water in reservoir Trouble shooting PROBLEM PROBABLE CAUSE REMEDY Pump is not working Unit may be out of w...

Page 7: ... 3 Keepers Stems set of 4 110871 4 Pump 110439 4 5 Drain plug assembly 110698 2 6 Water indicator float 110872 2 7 Swivel casters Non locking 110822 8 8 Swivel casters Locking 110822 9 9 Remote control 110101 2 12 Water distributor tubing 110734 1 To purchase parts call 1 800 643 8341 or visit XXXXXXXXX com 5 8 7 4 6 8 7 3 2 1 3 9 10 ...

Page 8: ... responsible for any incidental or consequential damage resulting from any malfunction We are not responsible for any damage received from the use of water softeners chemicals de scale material or plastic wrap We are not responsible for the cost of service calls to diagnose the cause of trouble or labor charge to repair and or replace parts How to Obtain Service Under this Warranty Contact the Dea...