 Problem 

Possible Cause 

Remedy

Failure to 
start or no air 
delivery

Inadequate 
air delivery 
with cooler 
running

Inadequate 
cooling

1.  No electrical power to 

unit

 • 

Fuse 

blown

 • 

Circuit 

breaker 

tripped

 

•  Electric cord un-

plugged or damaged

2.  Belt too loose or tight
3. Motor overheated

 

•  Belt too tight

 

•  Blower bearings dry

4. Motor locked

1. Insuffi cient air exhaust

2.  Belt too loose

3. Pads plugged

1.  Inadequate exhaust in 

house

2.  Pads not wet

 • 

Pads 

plugged

 

•  Open spots in pads

 • 

Trough 

holes 

clogged

 

•  Pump not working 

properly

1. Check power

 • 

Replace 

fuse

 • 

Reset 

breaker

 

•  Plug in cords or 

replace if damaged

2.  Adjust belt tension
3.  Determine cause of 

overheating

 

•  Adjust belt tension

 

•  Oil blower bearings

4. Replace motor

1.  Open windows or 

doors to increase air 
fl ow

2.  Adjust belt tension or 

replace if needed

3. Replace pads

1.  Open windows or 

doors to increase air 
fl ow

2. Check water distribu-

tion system

 • 

Replace 

pads

 • 

Repack 

pads

 

•  Clean trough and 

unplug holes

 

•  Replace or clean 

pump 

Troubleshooting

Motor cycles 
on and off

Noisy

Excessive 
humidity in 
house

Musty or 
unpleasant 
odor

Water drain-
ing from 
cooler

1. Low voltage
2.  Excessive belt tension
3.  Blower shaft tight or 

locked

4. Bearings dry

1. Bearings dry
2.  Wheel rubbing blower 

housing

3. Loose parts

1. Inadequate exhaust

1.  Stale or stagnate water 

in cooler

2.  Pads mildewed or 

clogged

3.  Pads not wetting 

properly

 • 

Trough 

holes 

clogged

 

•  Pump not working 

properly

1.  Float arm not adjusted 

properly

2.  Drain assembly leak-

ing

1. Check voltage
2.  Adjust belt tension
3.  Oil or replace bear-

ings

4. Oil bearings

1. Oil bearings
2. Inspect and realign

3.  Tighten loose parts

1.  Open doors or win-

dows

1.  Drain pan and clean 

pads

2. Replace pads

3. Check water distribu-

tion system

 • 

Clean

 

•  Replace or clean 

pump 

 
1. Adjust fl oat

2.  Tighten nut and drain 

cap.

 Problem 

Possible Cause 

Remedy

Model

Modelo

Volts

Voltios

Amperage

Ameraje

Speed

Velocidad

Water Capacity (gal)

Capacidad de Agua (galón)

Weight (lbs.)

Peso (libras)

Dry

Seco

Operating

Lleno

M201A

115

4.7

2

4.8

62

102

M301A / RM301A

115

7.9

2

9.2

107

184

M401A / RM401A

115

10.5

2

11.3

169

263

Specifi cations  /  Especifi caciones

Summary of Contents for M201A

Page 1: ...like refrigeration systems which recirculate the air an evaporative cooler continually brings in fresh air while exhausting old air You are completely replacing the air every 2 to 4 minutes by opening windows or doors or a combination of both The air is always fresh not stale laden with smoke and odors as happens with refrigerated air conditioning Vea el Español en el interior 110522 1 1 09 www ch...

Page 2: ...in the off state will return the fan and pump to their previous operating settings When first plugging in the cooler or after power has been interrupted pressing the On Off button will start the cooler in the default state which is with the pump on and the fan on high Remote Control To operate the cooler with the remote you must be within 20 feet and in sight of the cooler Aim the remote at the fr...

Page 3: ... the length of the season At the beginning and at mid season a clean pad is more absorbent and efficient and will deliver substantially more cool air Check belt and belt tension This applies only to models R M401Awhich are belt driven Models M201Aand R M301A have direct drive motors Check the belt for any cracks or wear and Float Body Float Rod Washer Nut Garden Hose Adapter Fig 3 Note Do Not Over...

Page 4: ...oles Replace or clean pump Troubleshooting Motor cycles on and off Noisy Excessive humidity in house Musty or unpleasant odor Water drain ing from cooler 1 Low voltage 2 Excessive belt tension 3 Blower shaft tight or locked 4 Bearings dry 1 Bearings dry 2 Wheel rubbing blower housing 3 Loose parts 1 Inadequate exhaust 1 Stale or stagnate water in cooler 2 Pads mildewed or clogged 3 Pads not wettin...

Page 5: ... Distributor Assembly Sistema Del Distribuidor De Agua 3D 1 3D 2 3D 3 35 Retaining Clip Water Distributor Retén Plástico Para El Distribuidor De Agua 110723 5 110723 6 110723 6 36 Drain Assembly Montaje De Desagüe 3DA 1 3DA 1 3DA 1 37 Float Valve Válvula Del Flotador FL C FL C FL C 38 Garden Hose Adapter Adaptador Para Manguera De Jardín 110824 110824 110824 39 Swivel Caster w Brake Rueda Giratori...

Page 6: ...6 110522 1 Parts Drawing Dibujo De Piezas M201A ...

Page 7: ...7 110522 1 Parts Drawing Dibujo De Piezas M301A RM301A ...

Page 8: ...sólo con corriente alterna de 120 voltios 60 Hz ciclos 4 El motor y la bomba están conectados con la tierra y se apagarán automáticamente en caso de sobrecalentamiento Los motores volverán a funcionar cuando se enfrían 5 Enchufe una bomba del enfriador evaporativo solamente y nada más al receptáculo de la bomba ADVERTENCIA Para reducir el riesgo de incendio o toques eléctricos no use este ventilad...

Page 9: ...sición PUMP El interruptor tiene seis posiciones Ajuste el interruptor a la posición PUMP bomba para poner en marcha la bomba sin el ventilador Para mejor resultado ponga en marcha la bomba por unos cuantos minutos para mojar los filtros antes de poner en marcha el ventilador Los posiciones HIGH COOLy LOWCOOL Ajuste el interruptor a la posición HIGH COOL o LOW COOL para poner en marcha el ventilad...

Page 10: ...enimiento ADVERTENCIA Antes de hacer cualquier mantenimiento compruebe que la unidad esté apagada y desconectada de la electricidad Esto es por su seguridad Mantenimiento Anual Lubrique los cojinetes Los cojinetes de la rueda M401A y RM401Asolamente y el motor del ventilador deben ser lubricados usando unas gotas de un aceite no detergente de densidad 20 30 una vez al año No obstante los motores s...

Page 11: ... rueda están secos 4 Motor parado 1 Insuficiente abertura para que salga el aire 2 Poca tensión en la correa 3 Filtros obstruidos 1 El agotamiento del aire es inadecuado 2 Los filtros no están mojados Filtros obstruidos Filtros agujereados Agujeros de los canales obstruidos Bomba no funciona 1 Revise la corriente Cambie el fusible Restablecer el cortacircuito Reemplace el cable 2 Ajuste la tensión...

Reviews: