POWER ASSISTED STEERING SYSTEM
-
page 33
of 143
Installation, Maintenance and Owner's Manual
ULTRAFLEX
E
N
G
L
ISH
40A fuse
(included in
the power
cable)
40A Magneto-thermal
switch
40A Magneto-thermal
switch
The
system features a very low electrical input: in any case, it is advisable to use an APS
(Automatic Power Selector) to use the charge of two batteries: in single-engine systems, the power cable
must be connected to the engine battery and to the service battery.
NOTICE
A 40A fuse is needed on each
APS power line
NOTICE
The magneto-thermal switches
must be as close as possible to
the power source
Masterdrive
Power
cable
APS
Fuse on
cable
Magneto-thermal
switch
Battery
disconnecting device
Engine
battery
Service distribution panel
Engine negative
ground bar
Engine
Service
negative
ground bar
Magneto-thermal
switch
Protecting
device
Service
battery
Protecting
device
Negative
pole
Positive
pole