Summary of Contents for CSC100BU

Page 1: ...Rev A CSMU000835 09 15 03 CSC100xU Series CSC110xU Series Covert Cameras USER MANUAL...

Page 2: ...IS PUBLICATION MAY BE REPRODUCED BY ANY MEANS WITHOUT WRITTEN PERMISSION FROM HONEYWELL VIDEO SYSTEMS THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPECTS HOWEVER HONEYWELL V...

Page 3: ...SHOCK DO NOT OPEN EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous volta...

Page 4: ...RM UP TIME 5 2 4 WALK TESTING THE DETECTOR 6 2 5 VOLTAGE REGULATION 6 SECTION 3 SPECIFICATIONS 7 USERS OF THE PRODUCT ARE RESPONSIBLE FOR CHECKING AND COMPLYING WITH ALL FEDERAL STATE AND LOCAL LAWS A...

Page 5: ...lity Built in voltage regulators prevent high voltage from reducing the life of the camera The following models are covered in this manual CSC100BU Covert Camera Black White Standard Resolution Non Fu...

Page 6: ...nt of bulky objects where camera view will be impaired 2 2 MOUNTING THE CAMERA The camera can be mounted directly to a wall or with an optional mounting bracket for greater maneuverability Contact you...

Page 7: ...E CAMERA CONTINUED PCB Screw Block Terminal CCD Connector GND VIDEO GND Vin Figure 1 PCB Layout CSC100BU CSC100CU Relay Grounding Jumper Relay DIP Switches LED Indicator CCD Connector PCB Screw Pyro S...

Page 8: ...INUED 3 Use the provided knockouts to assist in mounting the unit Use the side knockouts to mount the camera at an angle Knock outs Figure 3 Rear Housing Knockouts 4 Reattach the electronics board to...

Page 9: ...e the LED indicator after successfully walk testing the detector Relay Operation Selectable to Normally Open N O or Normally Closed N C If one side of relay grounding is required install the relay gro...

Page 10: ...to the detection pattern selected Since the pattern is determined by the lens used in the detector refer to the lens range diagram 2 Confirm that the LED activates then deactivates after 2 motion fre...

Page 11: ...ate S N Ratio 46dB Electronic Shutter 1 60 to 1 100 000 sec linear Gamma Correction 0 45 AGC ON Geometric Linearity No camera distortion picture linearity limited by lens and monitor Input Voltage 12...