background image

SECTION 3: 

INSTALLATION AND SETUP 

3.1 INSTALLATION 

DIAGRAMS 

 

Input

Input

Cam 16

Cam 1

Output

Output

Spot

Spot

Monitor

Main

Monitor

Main

KEGS5000 System Controller

RS-485

PSU

12 VDC 

500 mA

RS-232

KEGS5000 System Controller

VCR

KX1610CN Multiplexer

2 - RX (data in)

5 - Ground

2 - RX (data in)

5 - Ground

RS-232

RS-232

+12VDC

GND

RS-232 (RX)

RS-232 (TX)

RS-485 (D+)

RS-485 (D-)

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

GND

GND

RX (Data In)

RX (Data In)

DB9-Female

DB9-Male

+12VDC

GND

RS-232 (RX)

RS-232 (TX)

RS-485 (D+)

RS-485 (D-)

Ultrak # RE-RTD12/5RT 

+

-

 

 

Figure 4:  Installing the Ultrak Multiplexer, VCR, and Domes. 

519222-1960 7 

KEMU000499 

Rev. C 

 

08/23/02 

Summary of Contents for KEGS5000

Page 1: ...TUS NEW PUBLICATION ISSUE DATE X REVISED REISSUED PUBLICATION Replaces REV B PRINTING INSTRUCTIONS Mark appropriate options Paper Size 11 x 17 X Fold Staple Booklet Color White X Print Duplex Cover Ba...

Page 2: ...KEGS5000 System Controller USER MANUAL 519222 1960 KEMU000499 Rev C 08 23 02...

Page 3: ...E TX 75057 972 353 6500 www ultrak com ALL RIGHTS RESERVED NO PART OF THIS PUBLICATION MAY BE REPRODUCED BY ANY MEANS WITHOUT WRITTEN PERMISSION FROM ULTRAK THE INFORMATION IN THIS PUBLICATION IS BELI...

Page 4: ...AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN W...

Page 5: ...may be followed by any number of alphanumeric characters Small System Interface SSI 100 may be followed by any number of alphanumeric characters Control Output Expander COE 08 COE 16 may be followed...

Page 6: ...ert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 10 OVERLOADING Do not overload outlets and extension c...

Page 7: ...SITIVE DEVICE USE PROPER CMOS MOSFET HANDLING PRECAUTIONS TO AVOID ELECTROSTATIC DISCHARGE TO PREVENT ELECTRIC SHOCK DO NOT REMOVE THE GROUNDING PIN THIRD PIN ON THE POWER PLUG ON THE POWER SUPPLY CAU...

Page 8: ...E CONTROLLER 11 Default Password 11 4 2 SPOT MONITOR OPERATION 12 Absolute Mode 12 Relative Mode 12 Moving between Absolute and Relative Modes 13 4 3 PTZ OPERATION 13 View PreShot Recall 13 View PreSh...

Page 9: ...ERNATIONAL OFFICES ERROR BOOKMARK NOT DEFINED LIST OF FIGURES Figure 1 Controls of the KEGS5000 2 Figure 2 LCD and Soft Keys 6 Figure 3 Information Displayed on the LCD 6 Figure 4 Installing the Ultra...

Page 10: ...ve operation LCD Display User programmable macros Separate logins for Operators and Master Users supervisors Supported Ultrak VCRs KR4XXXXX Series Supported Multiplexers KX16XXCX series KQ7300CX KX04X...

Page 11: ...ptions ID Icon Usage Description 1 Numeric Keypad Used to enter numbers in programming screens and entering camera numbers monitor numbers and other device numbers 2 Plus Key Used to select the next c...

Page 12: ...er to Description by Mode VCR Pause Normal Focus Near Multiplexer 2 x 2 Multi Screen Display 9 Refer to Description by Mode VCR 0 0 0 Counter Reset Normal Focus Far Multiplexer 3 x 3 Multi Screen Disp...

Page 13: ...s the key again LED will not be lit 17 PTZ Dome Call Used to select the associated PTZ and PreShot for the current camera 18 View Used to recall a preprogrammed view or PreShot on the current dome or...

Page 14: ...HT FAST FORWARD LEFT REWIND 2 3 CONNECTIONS Description Power Supply The KEGS5000 can be powered from a DC power supply with a voltage range of 8 15V 500mA COM1 RS485 output port Used for controlling...

Page 15: ...ENTER BUTTON Used to select option shown on the right side of screen E RIGHT ARROW Use to move between menu items Once inside the menus use the ENTER key to select the menu Navigation of the menus wil...

Page 16: ...System Controller VCR KX1610CN Multiplexer 2 RX data in 5 Ground 2 RX data in 5 Ground RS 232 RS 232 12VDC GND RS 232 RX RS 232 TX RS 485 D RS 485 D 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 GND GND RX Dat...

Page 17: ...32 KD6 KD6Z Dome 1 5 5 1 1 9 9 6 6 6 6 9 9 1 1 5 5 DB 9 Female rear view of connector DB 9 Male rear view of connector DB 9 Male rear view of connector DB 9 Female rear view of connector Multiplexer...

Page 18: ...232 VCR cable connections RS 232 MUX cable connections RS 485 D RS 485 D RS 485 D RS 485 D 1 5 6 9 9 6 RS 232 to VCR RS 232 to MUX To KEGS5000 To KEGS5000 DB 9 Female rear view of connector DB 9 Male...

Page 19: ...must be set to match that set in the KEGS5000 Multiplexer Setup The multiplexer should be set up as follows Coms RS 232 Baud 1200 The address of the multiplexer with cameras 1 16 must be set at 1 came...

Page 20: ...all menus except those in which changes to system setup are involved The table below shows which menus and functions are available for each mode Description Operator Master Save PreShot View on KD6 Z...

Page 21: ...e 012 Example Routing a camera to the spot monitor of multiplexer 1 Example camera 12 1 2 OR 1 2 Spot01 Cam012 Save View 2 0 OR 2 0 Spot02 Cam020 Save View Note that SPOT now indicates that multiplex...

Page 22: ...View PreShot Recall The first 10 PreShots Views are available as scratchpad PreShots These can be saved and recalled by the operator PreShots Views 11 79 can only be recalled by the operator and not s...

Page 23: ...and hold ALT then use the joystick to move the text TIP To enter text into a menu such as the name of a PreShot press the AUX This enter a text mode on the LCD display Use the joystick to scroll throu...

Page 24: ...name of a PreShot press AUX This enters a text mode on the LCD display Use the joystick to scroll through the available letters Press Enter to send the text to the KD6 Use the ESC key to exit any menu...

Page 25: ...the AUX The LCD display changes to a text mode Use the joystick UP and DOWN to scroll through the letters of the alphabet Once the character is selected move the joystick to the right to move the curs...

Page 26: ...t the joystick LEFT to FAST FORWARD Reverse Play Play tape in reverse at regular speed Pause Pause tape playback 0 0 0 Counter Reset Reset VCR counter 1 2 3 Counter Memory Stop Stop VCR counter to mar...

Page 27: ...T to zoom in and LEFT to zoom out In Multiplexer Menu this key acts as the SET button Multiplexer Cursor The LEFT RIGHT UP and DOWN directions of the joystick mimic the multiplexer cursor keys Full Sc...

Page 28: ...additional options Using the figure the LCD shows that we are at the Multiplexer Menu which is menu 1 The More indicates that there are further options or sub menus available under this menu To select...

Page 29: ...Muxes 1 2 Number of Multiplexers One to 16 allowed Each multiplexer must have the address set at its logical number Press Recorders Menu Name Menu Number Description Recorders 2 0 Used to set the type...

Page 30: ...the four camera types KD6 KD6 Z Fixed Camera and Pan Tilt Head Press or on the joystick to move to the next sub menu TIP To make it easy to setup all camera TYPES and camera ADDRESSES start with camer...

Page 31: ...not stored in the controller The address of each KDZ dome can be set one after each other without having to exit this menu Passwords Menu Name Menu Number Description Passwords 5 0 Press to access th...

Page 32: ...this menu Buzzer 7 1 Use the and keys to toggle the buzzer ON or OFF Press to exit this menu Language 7 2 Use the and keys to scroll through the language options Press to exit this menu Exit Menu Nam...

Page 33: ...Program Files Ultrak Code Server CCTV KEGS5000 If Code Server was installed to a different drive select the drive prior to installing The latest version will be saved to your computer 1 Connect the KE...

Page 34: ...6 From the START bar on your PC select Programs Ultrak Ultrak Code Server The following window appears Figure 7 Ultrak Code Server window 7 The Port Properties icon allows you to select which serial...

Page 35: ...alid port number error message This is because the port is being used by another device usually the mouse or a modem Click on the properties icon and select a different port Figure 10 Invalid Port Err...

Page 36: ...ED 10 Click on the Transmit Hex File icon to bring up the Send Hex File window Figure 12 Send Hex File window 11 Double click the CCTV folder and then the KEGS5000 folder Figure 13 Selecting the Hex F...

Page 37: ...le being transmitted and the progress of the download Download Busy appears on the KEGS5000 LCD Figure 14 Sending Hex File status window 13 When the download is complete a Transfer Complete window wil...

Page 38: ...allation and the problem has been isolated to the controller then it must be removed for servicing THERE ARE NO USER SERVICEABLE PARTS REFER SERVICING TO QUALIFIED PERSONNEL ONLY 6 2 PREVENTIVE MAINTE...

Page 39: ...NOTES 519222 1960 30 KEMU000499 Rev C 08 23 02...

Page 40: ...S 485 and 1xRS 232 port Communication Speed RS 232 1200 baud RS 485 9600 baud Control Output Modes RS 232 for Multiplexers and VCRs RS 485 for Domes and PTZs Operating Distances 4000 ft 219 m with RS...

Page 41: ...75 2800 Fax 61 0 8 9478 4500 sales ultrak com au Ultrak Germany Gro enbaumer Weg 8 40472 D sseldorf Germany 49 0 211 41 50 90 FAX 49 0 211 42 40 19 info ultrak germany com Ultrak Italy Via Treviso 2 4...

Reviews: