background image

It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not 
build up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular 
cleaning will not only ensure the maximum light-output, but will also allow the fixture to function reliably 
throughout its life.A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, 
under no circumstances should alcohol or solvents be used!

The front objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing 
the light-output very quickly. The cooling-fans should be cleaned monthly.

The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.

Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-cleaner.

.

10.Maintenance and cleaning

DANGER !

Disconnect from the mains before starting any

maintenance work

SPOT 

 WHITE

Summary of Contents for SMART SPOT100 Series

Page 1: ...ANUAL carefully before using this product Be sure to keep the USER MANUAL properly for future needs Use this product correctly when you can fully understand the User Manual SMART SPOT100 WHITE 3000 K 5600 K ULSSF100CW ULSSPC100CW ULSSF100WW ULSSPC100WW ...

Page 2: ...The electric connection repairs and servicing must be carried out by a qualified employee Do not connect this device to a dimmer pack Do not switch the fixture on and off in short intervals as this would reduce the lamp s life During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Do not touch the device s housing...

Page 3: ...new type of high temperature strength and cast aluminum casing with nice outlook The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for operation And it is applicable for large scale live per formances theater studio nightclubs and discos This manual cover...

Page 4: ...3 TECHNICAL INFORMATION 03 SPOT WHITE 297 225 300 ...

Page 5: ...evice installation Ÿ Ensure that the appliance is operated by qualified personnel who know the appliance before use Ÿ Keep the original packaging if a second shipment is required Ÿ Do not try to change the projectors without any instruction from the manufacturer or repair appointed agencies Ÿ It is not in the warranty interval if there are malfunctions not to follow the user manual to operate or an...

Page 6: ...tion below Be sure this fixture is kept at least 0 5m 1 5 f t away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Mounting points Mounting the projector requires extensive experience including amongst others calculating working load limits a fine knowledge of the i...

Page 7: ...am below DMX 512 connection with DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 3 resistor connected between pins 2 and 3 w...

Page 8: ...to set the flickering frequency from 1000 to 5000 Hz besides the default value NOTE DMX signal goes ahead this setting it permits the reset of the unit Keepin pressed ENTER and MENU at the turningon of the unit it allows to access ALIG features Sure it restores all the setting at default value excepting of led settings and hour meter ID da 1 a n Disables the adjusting of the leds settingthem at max...

Page 9: ...ng 2500Hz LED control frequency tuning 3000Hz LED control frequency tuning 3500Hz LED control frequency tuning 4000Hz stop strobe random strobe effect with variable speed from slow to fast non syncronised colors 5 special functions step 600 Hz park no effect LCD display off LCD display on LED control frequency tuning 1000Hz 4 strobe no effect variable speed strobing effect from slow to fast stop s...

Page 10: ...any good glass cleaning fluid is recommended under no circumstances should alcohol or solvents be used The front objective lens will require weekly cleaning as smoke fluid tends to building up residues reducing the light output very quickly The cooling fans should be cleaned monthly The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet Remove dust and di...

Page 11: ...e been checked and are produced in compliance with the Directive in question Reference Title 2004 108 EC Directive of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC EMC 2006 95 EC Directive of the European Parliament and the Council of 12 December 2006 ...

Page 12: ...ULTRALITE DEUTSCHLAND Haerle Lichttechnik GmbH Marie Curie Str 4 89584 Ehingen Germany 49 7391 7747 0 www ultralite eu info ultralite eu ...

Reviews: