background image

Level I Programming

27

Rev A

Setting Day of Week

After setting the Time of Day the banner display will show the word 
“Day” followed by an abbreviated day of the week.
SU = Sunday
MO = Monday
TU = Tuesday
WE = Wednesday
TH = Thursday
FR = Friday
SA = Saturday

Use the UP or DOWN arrow buttons to change the flashing day of 
week. Press the SET button when the current day of week is flashing.

Setting Regeneration Time

The "Regeneration Time" is the setting which allows the programmer 
to select the time of day that regeneration should occur. The words 
“Regeneration Time” will scroll through the banner display. To change 
the regeneration time press and hold the UP or DOWN button until the 
desired regeneration time is displayed. Press SET to lock this time into 
memory.

NOTE:  

When the controller is set up for a twelve hour clock a PM 

indicator will illuminate when the displayed time is in the PM hours. 
There is no indicator for the AM times.

Summary of Contents for 263 Three-Cycle Filter

Page 1: ...Models 268 Co Current Conditioner 263 Three Cycle Filter Operations Manual...

Page 2: ...2 Drain Line 14 Regenerant Line Connection 15 Overflow Line Connection 16 Electrical Connection 18 Valve Camshaft 19 Disinfection Of Water Conditioners 20 Ultramax Controller 22 Display Icons 23 Keypa...

Page 3: ...equipment should have Knowledge of water conditioning and how to determine proper control settings Basic plumbing skills The directional instructions left and right are determined by looking at the fr...

Page 4: ...on connections that do not use an O ring seal Do not use pliers or pipe wrenches All plumbing must be completed according to local codes Soldering near the drain line should be done before connecting...

Page 5: ...e acceptable working water pressure range is 20 to 100 psi 1 38 to 6 89 bar Use only regenerant salts designed for water softening Do not use ice melting block or rock salts Follow state and local cod...

Page 6: ...njector and brine is drawn from the regenerant tank The brine is then directed down through the resin bed and up through the riser tube to the drain The hardness ions are displaced by sodium ions and...

Page 7: ...System Operation Cycle Functions 7 Rev A Cycle Water Flows SERVICE BACKWASH BRINE SLOW RINSE FAST RINSE From Regenerant Tank To Regenerant Tank BRINE REFILL REPRESSURIZE...

Page 8: ...nstallation Valve Layout Refill Controller Regenerant Tube Connection Injector and cap Valve Discs Outlet Drain Inlet Backwash Injector Screen Camshaft Drain Control Filter Control Module Mount One Pi...

Page 9: ...N KG x100 LCD Display Manual Regen Button Down Button Set Button Up Button Lockout Connection Turbine Input or Dry Contact Signal Input Main Motor Optical Sensor Connection AC Adapter low voltage Inpu...

Page 10: ...onditioning system is installed outdoors several items must be considered Moisture The valve and controller are rated for NEMA 3 locations Falling water should not affect performance The system is not...

Page 11: ...oller and valve have been designed to keep all but the smallest insects out of the critical areas Any holes in the top plate can be covered with a metal foil ductwork tape The top cover should be inst...

Page 12: ...s Figure 1 Autotrol Series 1265 bypass for use with Performa Figure 2 Typical Globe Valve Bypass System Normal Operation In Bypass B Y P A S S B Y P A S S B Y P A S S B Y P A S S Water Conditioner In...

Page 13: ...sed only hand tighten the nuts WARNING Do not use petroleum grease on gaskets when connecting bypass plumbing Use only 100 silicone grease products when installing any Autotrol brand valve Non silicon...

Page 14: ...tional 10 psi 69 bar of water pressure at the drain connector 4 Where the drain line is elevated but empties into a drain below the level of the control valve form a 7 inch 18 cm loop at the far end o...

Page 15: ...in out and the conditioner will not draw regenerant from the tank This may also introduce air into the valve causing problems with valve operation Ensure that pipe sealant Teflon tape is applied to th...

Page 16: ...ct the overflow line locate hole on side of tank Insert overflow fitting into tank and tighten with plastic thumb nut and gasket as shown Figure 5 Attach length of 1 2 inch 1 3 cm I D tubing not suppl...

Page 17: ...Overflow Line Connection 17 Rev A Figure 6 Regenerant Tank Check Valve not used with 3 cycle filter system Furnished as an option from system manufacturer...

Page 18: ...or attached to a flat surface Installations that do not provide easy access to the valve can have the controller mounted for remote operation A remote mount connection PN 1256257 is available for the...

Page 19: ...ont End for 263 and 268 valve bodies The corresponding slot for the number is positioned at the optical sensor which is approximately 90 degrees out of phase Regeneration Cycle Indicators 0 Treated Wa...

Page 20: ...e following methods Sodium or Calcium Hypochlorite Application These materials are satisfactory for use with polystyrene resins synthetic gel zeolite greensand and bentonites 5 25 Sodium Hypochlorite...

Page 21: ...used directly without dissolving before use 1 Dosage A Two grains approximately 0 1 ounce 3 mL per cubic foot 2 Regenerant tank conditioners A Backwash the conditioner and add the required amount of...

Page 22: ...ent power conditions Controller Memory Information entered or calculated by the controller is stored in two different ways A static memory will store Model number Regenerant setting Time of regenerati...

Page 23: ...ts 4 When LBS is displayed the value entered is in pounds 5 When Kg is displayed the value entered is in kilograms or kilograins 6 Four digits used to display the time or program value Also used for e...

Page 24: ...roller is programmed using the buttons on the keypad The programming instructions will be described two ways whenever a section has keypad input First a table shows simplified instructions Second text...

Page 25: ...see the Level II Programming section The controller can be programmed to regenerate on specific days of the week See Level II Programming section If electrical power is not available the camshaft can...

Page 26: ...on They include Time of Day Day of Week Time of Regeneration Setting Time of Day Upon initial start up of the controller you will need to set the time of day The words Time of Day will scroll across t...

Page 27: ...k is flashing Setting Regeneration Time The Regeneration Time is the setting which allows the programmer to select the time of day that regeneration should occur The words Regeneration Time will scrol...

Page 28: ...KWASH OPERATION TYPE 268 FAST RINSE SERVICE INTERVAL OPERATION TYPE 263 CHLORINE GENERATOR SERVICE INTERVAL CHLORINE GENERATOR View only Level II parameters will in almost all cases be preset to meet...

Page 29: ...operate custom systems Contact your Ultramax Water Treatment Dealer before adjusting the capacity setting Default capacities are shown in Table 1 Filter Capacity Filter capacity is set in gallons or c...

Page 30: ...o operate in U S or Metric units Program the Units of Measure to 0 zero for U S units or 1 for Metric units Viewing the Injector Type Is selected by system model number and cannot be changed Adjusting...

Page 31: ...ler to program the unit to ask for maintenance after a programmed duration The feature is programmed from 0 zero to 99 months When the programmed length of time has been reached the words CALL DEALER...

Page 32: ...ense if there is any brine present during the time when brine draw is occurring This parameter can be adjusted to the following 0 Chlorine Generator with Salt Check disabled 1 Chlorine Generator with...

Page 33: ...8 263 MODEL NUMBERa See Salt Capacity Table X X DAYS SINCE REGENERATION 0 to 255 days X X PEAK FLOW RATE DAY AND TIME Language Clock Mode Dependant X PEAK FLOW RATE GPMa 0 to 47 GPM X WATER TREATED TO...

Page 34: ...banner display indicating that the motor is running Additionally the display will show the total regeneration time remaining Pressing SET when the motor has stopped displays the cycle description and...

Page 35: ...generant tank If the tank has a salt platform in the bottom of the tank add water until the water level is approximately 1 inch 25 mm above the platform WARNING If opened too rapidly or too far media...

Page 36: ...m the regenerant tank A From the treated water position initiate a manual regeneration The controller will begin a manual regen and advance the control valve to the backwash cycle Press the SET and UP...

Page 37: ...Performa Exploded View 37 Rev A Performa Exploded View 2 1 3 4 5 6 7 8 9 10A 11 12 13 14 16 17 18 15 19 10B 11 Warning Do not use the flow control ball with 10A 22 23 21 20...

Page 38: ...s Controller 12 V 50 60 Hz 1035733 H Injector High Efficiency Lt Purple 19 1001986 13 16 inch Rubber Insert Optional 1 9 inch tank 20 1235446 Turbine Cable 1 1035734 J Injector High Efficiency Lt Blue...

Page 39: ...connected Verify that motor wire harness is connected to motor and controller module Verify that optical sensor is connected and in place Verify that motor gear has engaged cam gear If everything is...

Page 40: ...d a Make correct setting according to instructions b Remove restriction c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closi...

Page 41: ...lean water Turbine should spin freely If not replace meter Contact dealer 13 Run out of conditioned water between regenerations a Improper regeneration b Incorrect regenerant setting c Incorrect hardn...

Page 42: ...42 Troubleshooting Rev A...

Page 43: ...orm the following steps 1 Press the DOWN and SET buttons simultaneously and hold for 5 seconds 2 After 5 seconds the controller will go blank Release the buttons and the controller will scroll MODEL N...

Page 44: ...Copyright 2005 General Electric Company Printed in USA P N 3002774 Rev A...

Reviews: