Summary of Contents for UP120AC DUO

Page 1: ...UP120AC DUO CH1 120W CH2 100W AC DC 10 0A Multi Charger Multi Charger Built in Power Supply UP120AC DUO INSTRUCTION MANUAL 1 2 0 W 1 0 0 W AC DC 1 2 0 W 1 0 0 W AC DC...

Page 2: ......

Page 3: ...Discharging Lithium Battery 17 Pb Battery Program 18 Charging of Pb Battery 18 Discharging of Pb Battery 18 NiMH NiCD Battery Program 19 Charging of NiMH NiCD Battery 19 Charging NiMH NiCD Battery in...

Page 4: ...operating area Make sure you know the specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery an...

Page 5: ...l or 7 4V in series Have you checked that all connections are firm and secure Make sure there are no intermittent contacts at any point in the circuit Standard Battery Parameters Be very careful to ch...

Page 6: ...as it covers a wide range of information on operation and safety INTRODUCTION Input voltage AC 110V or 220V DC 11 0 18 0V Max 120W 10W CH1 Max 100W 10W CH2 0 1 10 0A 0 1 5 0A 300mA cell 1 6 series 1...

Page 7: ...TION 5 LCD Screen Battery Sockets Battery Sockets DC Input 11 18V DC Balance Socket Temp Sensor AC Input 100 240V AC Cooling fan with Temp Sensor Control Menu Control Buttons PC Link PC Link DC Output...

Page 8: ...the voltage of any single one cell is abnormal Adaptable to Various Type of Lithium Battery UP120AC DUO is adaptable to various types of lithium batteries such as LiPo LiIon and the new LiFe series o...

Page 9: ...hreshold the process will be terminated automatically Automatic Charging Current Limit You can set up the upper limit of the charging current when charging your NiMH or NiCd battery it is useful for t...

Page 10: ...the charge lead should be of adequate conductor cross section and high quality connectors which are normally goldplated should be fitted to both ends Always refer to the manual by the battery manufac...

Page 11: ...s to protect them Some rechargeable batteries have a memory effect If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their...

Page 12: ...attery it is absolutely essential to check one last time that you have set the charging parameters correctly If the settings are incorrect the battery may be damaged and could even burst into flames o...

Page 13: ...d If in doubt as to which socket to use please ask your dealer for clarification 5 Start the charge cycle wait and watch that the charger starts to charge and shows correct readings on the screen 6 Wh...

Page 14: ...URRENT 3 3A DSCHCURRENT 1 5A DSCHVOLTAGE 1 7V CELL SAVEPROGRAM ENTER PROGRAMSELECT PbBATT ENTER START PbCHARGE 2 0A 2 0V 1P PbDISCHARGE 0 1A 2 0V 1P PROGRAMSELECT NiCDBATT NiCDCHARGE CURRENT 2 0A ENTE...

Page 15: ...DE This function is for balancing the voltage of lithium polymer battery cells while charging In the balance mode the battery needs to connect to the battery s power lead with balance wire In this mod...

Page 16: ...ou choose The value on the left of the second line of the charger is current the user sets After setting the current and voltage press the START ENTER button for more than 3 seconds to start the proce...

Page 17: ...ore than 3 seconds to start the process This displays the number of cells you set up and the processor detects R Number of cells detected by charger S Number of cells set by you at the previous screen...

Page 18: ...you at the previous screen If both numbers are identical you can start charging process by press START ENTER button If not press BATT TYPE STOP button to go back to previous screen to recheck the numb...

Page 19: ...ber of cells detected by charger S Number of cells set by you at the previous screen If both numbers are identical you can start charging process If not press BATT TYPE STOP button to go back to previ...

Page 20: ...ore than 3 seconds to start discharging This program is only suitable for charging Pb lead acid battery with nominal voltage from 2 to 20V Pb lead acid battery is a completely different from NiMH NiCD...

Page 21: ...an press Inc or Dec button to change the parameter value press START ENTER button to store the value The screen displays the real time charging status Press BATT TYPE STOP button to stop the process T...

Page 22: ...indicates the end of process Re peak cycle number 1 shows on the display Press the START ENTER button to make the re peak cycle number blink and press INC or DEC button to find the desired number of...

Page 23: ...ound alerts the end of discharging You can set up sequence on the left and the number of cycles on the right Range of the cycle number is 1 5 Press BATT TYPE STOP button to stop program you can press...

Page 24: ...t blink and use INC or DEC to set up the parameter The example is Lipo battery pack 2S 7 4V Set the voltage and number of cells along with the normal voltage 1S 6S Set the charge current it can be adj...

Page 25: ...dicate the saved profile This program is to load the data stored at the save data program Press the START ENTER button more than 3 seconds to load a memory otherwise you only enter to the setting mode...

Page 26: ...harger with main battery lead and balance wires to balance socket Press the START ENTER button to enter the Lithium Battery Meter program The screen indicate each cell s voltage The screen indicate th...

Page 27: ...e program can insert a time delay to occur after each charge and discharge process to allow the battery adequate time to cool down before being subjected to the next process The value ranges from 1 to...

Page 28: ...ttons to confirm your action The beep or melody sounded at various times during operation to alert different mode changes These audible sounds can be on or off This program monitors the voltage of inp...

Page 29: ...y is connected with balance lead you can check voltage of each cell in the battery pack VERSION 1 00 LOAD FACTORY SET ENTER Ext Temp 0C Int Temp 26C 4 19 4 15 4 18V 0 00 0 00 0 00V VARIOUS INFORMATION...

Page 30: ...acity which the user sets The charging time is longer than the maximum charging time which the user sets The battery voltage is higher than the maximum voltage which the user sets when charging in bal...

Page 31: ...ial or operational defects which are present at the time of purchase During that period we will repair or replace free of service charge for products deemed defective due to those causes You will be r...