Whether the load is connected to the mold during the frequency search, because the device

searches for the resonance frequency with a very low amplitude. If a load is connected (such

as searching for frequency in water), the driving capability is not enough to promote the load

to obtain correct feedback. Please load search frequency
Reset a higher frequency and manually search the frequency
Inspect the welding head for cracks, unlocked, silk, and dirty.
Check whether the direct connection between the generator and the load is not connected,

disconnected or disconnected.
Check that the contact surface between the welding head and the horn is smooth and flat.
Replace a normal welding head test to confirm that the equipment works normally, check

whether the resonance frequency of the welding head is within the allowable frequency range

of the equipment, such as 20k models between 18.5k and 21.5k

6.2 Error: Phase lock out of DAC fine-tuning range

Triggering this protection means that the resonance frequency cannot be found or the

frequency has been locked when the system is adjusting the frequency in real time.
When this error occurs, try:

Reduce the load, such as reducing the size of the mold, the air pressure value in the plastic

welding machine mode, etc.

Increase the amplitude and use a higher voltage to push it.
Replace the horn with a ratio of 1: 2 or less. This is what we recommend. The traditional 1:

3 horn is more suitable for traditional self-excitation ultrasound.

Re-search the resonance frequency and set the frequency to work at the resonance

fre 0.06khZ.

Check for other possible causes, such as abnormalities in connecting wires, molds,

transducers, voltage, etc.

6.3 Error: excessive power consumption

During the working process, the system will detect the real-time power in real time, and

immediately protect it when the power exceeds the rated power of the equipment, so as not to

damage the equipment.
When this error occurs, try:

Re-search the frequency and check whether the current and power are out of range under

the sonic test. The specific values can be found in this article.

Excessive load, such as large mold plus heavy load (such as water load), exceeds its own

safe power output range to provide protection

The mold or generator is abnormal, such as the mold is cracked but not completely

damaged. At this time, the resonance characteristics are deteriorated, the power consumption

is increased, but the actual amplitude is small.

The amplitude is too large. A large amplitude means a large driving voltage. In addition, the

power output of some loads needs to increase sharply. If it exceeds the range, the amplitude

is appropriately reduced.

If it is confirmed that the load is too large or the amplitude is too large and this parameter

must be used, please consider using other high-power models of our company.

6.4 Error: over temperature

Summary of Contents for JYD-2700S

Page 1: ...anual I Basic information introduction II Environment Requirements III Connecting ports introduction IV Display interface and parameter introduction V The most common setup process for welding applica...

Page 2: ...ght 7KG Color light grey Features Automatic frequency tracking The system automatically tracks the resonance frequency of the welding head Compensate for detuning caused by heat and other reasons Digi...

Page 3: ...ature 25 C to 70 C Relative temperature 30 to 90 without condensation warning To ensure that the ultrasonic generator has good ventilation care must be taken not to cover the generator s ventilation o...

Page 4: ...7 8 can share a line Attention The power plug must be inserted into a socket with a ground terminal The adaptable power supply range of the ultrasonic signal generator is 220VAC 10 50 60Hz By adjusti...

Page 5: ...utput power of the whole machine Production Used to record production yield Only the number of times the entire welding process has been performed is recorded Emergency stops during the welding proces...

Page 6: ...whether the power is within 500W and whether the sound is mainly based on crisp model frequency sounds If you report an error that is out of range you should check the mold or transducer for abnormal...

Page 7: ...the horn with a ratio of 1 2 or less This is what we recommend The traditional 1 3 horn is more suitable for traditional self excitation ultrasound Re search the resonance frequency and set the freque...

Page 8: ...ls and perform frequency search Check if the mold is damaged Disassemble the mold or replace it with a mold that is confirmed to be good and check again Whether the load is short circuited Check wheth...