10” Automatic Round Damper

CLF-2985  

10" Automatic Round Damper (ARD) 110V 

CLF-2986  

10" Automatic Round Damper (ARD) 220V

The 10” Automatic Round Damper (ARD) is an inline damper that will open or close 
to allow or prevent fog from flowing down a run of 10” ducting.  

See ARD Manual 

for complete operating instructions.

  

10" Automatic Round Damper

CLF-9040 10" Fog Curtain Coupler
Are these the plastic clamshell type?? 

CLF-9039 10" Rigid Pipe (10' Length)
The 10" Rigid Pipe is ideal for long runs or permanent installations as it creates less 
internal turbulence  than the flexible 10” hose. It can be easily cut to length for 
installation with a reciprocating saw.

10" Rigid Pipe (10' Length)

CLF9045 Fog Curtain Metal Bracket
The Fog Curtain Metal Bracket acts as a coupler to join 2 10" rigid pieces together, 
and as a point to hang the fog curtain from (additional field supplied hardware is 
necessary). 
For a more rigid connection a CLF9032 4 1/2" Sleeve can be used in conjunction to 
stiffen the joint. 
A CXP4088 – Fog Curtain Foam Gasket may be required if fog leakage at the joint 
happens (sold Separately) 

CLF9050 Fog Curtain End Plate Plastic
The Fog Curtain End Plate Plastic is used to terminate the run on any 10" rigid piece.
A CXP4088 – Fog Curtain Foam Gasket is included to minimize leakage at the 
connection.

CXP4088 – Fog Curtain Foam Gasket 
Fog Curtain Foam Gasket may be required if fog leakage at the joint happens.

Fog Curtain Metal Bracket

Fog Curtain End Plate Plastic

Fog Curtain Foam Gasket 

Summary of Contents for Fog Curtain System

Page 1: ...v 092020 Fog Curtain System Operators Manual...

Page 2: ...tructions 1 Safety Precautions 1 Fog Curtain Components 2 Fog Curtain Design Example 4 Design Considerations 4 Maintenance 5 Trouble Shooting 5 Warranty 6 Contact Information 7 Note Please read entire...

Page 3: ...rgency 6 Fog effects will trigger smoke alarms and detectors Please take suitable precautions to prevent false alarms 7 Ensure sufficient air exchange vs CO2 released CO2 is heavier than air and will...

Page 4: ...gree branch CLF 9036 10 90 Elbow Long radius 90 elbow CLF 9038 10 Fog Curtain Pipe 10 Length w Holes The 10 Fog Curtain Pipe is the heart of the fog curtain system The fog curtain pipe with its airflo...

Page 5: ...ngth CLF9045 Fog Curtain Metal Bracket The Fog Curtain Metal Bracket acts as a coupler to join 2 10 rigid pieces together and as a point to hang the fog curtain from additional field supplied hardware...

Page 6: ...hine when the low fog cue is ended While the fog cue is running the 10 ARD is in the closed position directing the low fog to the fog curtain When the fog cue ends open the ARD and allow the fog to fl...

Page 7: ...ir Ultratec Special Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for indicating this request and for...

Page 8: ...ice Ultratec Special Effects GmbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special...