background image

www.ultratecfx.com 

9

Liquid Carbon 

Dioxide

Liquid Siphon 

Tube

Operation Procedure 
LSG MK II Low Pressure w/ 350lbs Dewar Tank

The Operation Procedures outlined in this section, refer to Figure B on Page 11.

1.  Place the fog machine’s output nozzle firmly against the center of the foam ring sealing it to the input port of the 

LSG MK II.

Tech Tip:

 Proper alignment can be observed by shining a flashlight into the 10” exit port of the LSG MK II and noting 

the fogger’s output nozzle is centered on the LSG MK II input port.

2.  Connect the grey Twist lock connector from the LSG MK II into the controlling power source (i.e. control port on 

the rear panel of the Power Fog Family of Ultratec Special Effects Foggers). This port can be controlled via DMX, the 
Timer/ Duration Remote or the Show Control Remote.

Note:

 Starting the flow of CO2 before the fog allows the liquid CO2 to purge the gas CO2 from the lines.  The Liquid 

CO2 is required for correct operation. The rule of thumb formula for calculating the purge time is 1 second for every 
three feet of hose. As the liquid sits in the hose unused it absorbs heat and converts to its gas state.

3.  Use Molecular Fog Fluid and adjust the flow rate to desired fog output level. Excessive fog flow will not cool 

sufficiently allowing the fog to rise off of the floor.

4.  An LSG MK II Low requires low pressure Liquid CO2 tanks. These are normally available in a 350lb size.  These are 

large vacuum tanks which keep the Liquid CO2 cold. Some CO2 is consumed during storage to maintain the liquid 
at -50C. These tanks provide the best performance and price characteristics of the LSG systems. Check with your 
local gas supplier for availability as not every location may carry these tanks.

Warning:

 Wear eye protection and gloves to protect against cold and pressure hazards.

5.  You must connect the supply hose to the liquid output of the liquid CO2 tank.  This is usually clearly indicated on 

the Liquid CO2 Tank outputs.  A sealing washer is necessary to prevent leaks and is available from your gas supplier.

6.  Tighten the CO2 supply-fitting tight with the appropriate wrench.

7.  The tank pressure is indicated on the pressure gauge and must read between 275 - 340 PSI to operate the LSG 

MK II. This is achieved by opening the Pressure Builder Valve (by turning it counter clockwise) at least 1-3 hours in 
advance.

8.  Open the valve slowly counter-clockwise until flow can be heard. Verify the lines have no leaks before opening the 

valve fully. 

9.  When the fog machine is up to operating temperature, activate the control to start the CO2 for the desired purge 

and pre-chill time.  Purging of the CO2 gas can be noted by the change in the flow sound. It is often desirable to 
pre-chill the chamber and long runs of ductwork (i.e. Fog Curtain). Now add fog to create the thick, white rolling 
blanket that hugs the floor.  On the Power Fog Family of Ultratec Special Effects Foggers, the CO2 is triggered by 
DMX (DMX c 1) or by one of the remotes. To control using the remote, the DMX address is selected as 555.  
This allows the Duration knob (turned up over 1/2 way) of the Timer/ Duration Remote or the second channel of the 
Show Control Remote to trigger the LSG MK II.

Summary of Contents for LSG PFI-9D

Page 1: ...LSG Low Smoke Generator w Power Fog Industrial 9D Operator s Manual www ultratecfx com VER 04 11 12...

Page 2: ...ating Procedure w Air Option 6 Operation Procedure LSG MK II High Pressure w 20 50lbs Cylinders 7 Figure A 8 Operation Procedure LSG MK II Low Pressure w 350lbs Dewar Tank 9 Figure B 10 Options 11 Opt...

Page 3: ...fering from asthma or allergenic sensitivity may experience irritation discomfort or allergic symptoms when exposed to fog effects 4 Ensure that this unit is grounded at all times Failure to do so may...

Page 4: ...Volt High Pressure PFI 9D System w Road Case CLF 4427 LSG Low Smoke Generator PFI 9D 220 240 Volt High Pressure PFI 9D System w Road Case LSG PFI 9D System on a Cart CLF 4431 LSG Low Smoke Generator...

Page 5: ...www ultratecfx com 5 LSG PFI 9D System in a Roadcase 39 5 28 75 34 5 23 25 29 6 24 20 36 32 2 22 28 02 LSG w PFI 9D Technical Drawings LSG PFI System on a Cart...

Page 6: ...s the fog machine will be fully heated and is ready for full output the indicator will be on solid 6 It may be necessary to prime fluid into the system to expel any air The Variflow control on the rem...

Page 7: ...cure all cylinders to prevent tipping hazards 4 An LSG MK II High Pressure requires high pressure CO2 cylinders These are normally available in 20 50lb sizes It is recommended that cylinders equipped...

Page 8: ...MK II to depressurize the system before attempting to disconnect hoses Note that the valves and lines may be extremely cold during operation Prevent handling and flexing of lines when chilled Figure A...

Page 9: ...intain the liquid at 50C These tanks provide the best performance and price characteristics of the LSG systems Check with your local gas supplier for availability as not every location may carry these...

Page 10: ...ger the LSG MK II to depressurize the system before attempting to disconnect the hoses Note that the valves and lines may be extremely cold during operation Prevent handling and flexing of lines when...

Page 11: ...Adapter CXP 1046 is available This adapter is compatible with the Power Fog Industrial Power Fog Industrial w Air Option Power Fog Industrial 9D and Power Fog Industrial 9D w Air Option Optional Show...

Page 12: ...ready to operate but still in heating mode fog is not available at this point Quick Flashing Light Indicates unit is ready to operate but still in heating mode some fog is available at this point Soli...

Page 13: ...e dry and odorless Pro Beam Long Lasting Fog Fluid With a hang time 2 3x greater than the Director s Choice Fog Fluid the Pro Beam solution produces a slightly less white fog while remaining clean dry...

Page 14: ...y is based on destination of the original sale Any additional costs incurred are the responsibility of the Dealer and or the customer Abuse or poor maintenance is not accepted Proof of purchase or pro...