Determining Installation:
The Solaris Air Ionizer is uniquely designed to be installed either internally or externally to
most HVAC systems. External mounting is typically done when metal return ducting is pres-
ent. Installing the Orion prior to any system filtration ensures that any charged particulate
matter will collect into the HVAC filter.
The Air Ionizer system may also be installed internally on most furnace and air-conditioning
systems.
The installing contractors take all installation and equipment variables into consideration
when determining the final installation point.
Preparation for external mounting only:
Use the external adapter plate when installing the Air Ionizer to metal duct work. First rotate
the probes 90 degrees. Use the supplied self tapping 10-32-1/4” screw. Attaching the plate
ensures that there will be no air leakage from the duct work after the installation.
External plate
Rotate probes 90 degrees
Attach bracket
Air flow should pass over both probes at the same
time for optimum performance
Installation Procedure
1. Disconnect main power to the HVAC system(turn applicable breakers off)
2. Determine a location on the duct, use a pencil to mark the location of both probes on
the duct work.
3. Drill 2 1/4 dia. holes. 4. Mount the Orion with supplied screws
5. Attach power cord
6. Attach leads of power cord to a Solaris IAQ Module (sold seperatly) or a 24 VAC
(min 10 va)transformer (polarity is not a concern).
7. Restore power
8. The Air IonizerWW has a white power indicator on the front of the label (ensure that
the led is illuminated).
IMPORTANT:
Probes should be a minimum of
1-1/2 inches from any metal.
Electrical Requirements
This product operates on 24 VAC
It is recommended to connect to a dedicated transformer.
if connecting to the Solaris IAQ module - connect only to the designated port
labled “ Air Ionizer”
Preparation for internal mounting only:
Attach the magnet to the Air Ionizer with the supplied 10-32-1/4” screw. You can also use
supplied self tapping screws to permanently mount the Orion.
Important! Note the position of the probes
Note the location of the
probes for proper air flow
Installation procedure:
1. Disconnect main power to the HVAC system(turn applicable breakers off).
2. Remove access door to the equipment
3. Mount the Air Ionizer either with the magnet or with supplied screws
4. Attach power cord.
5. Attach leads of power cord to a Solaris IAQ Module (sold seperatly) or a 24 VAC
(min 10 va)transformer (polarity is not a concern).
6. Restore power
7. The Air Ionizer has a white power indicator on the front of the label (ensure that the
led is illuminated).
Maintenance:
Periodically it is recommended to clean the brushes to ensure years of optimum perfor-
mance. This is a common practice when changing the HVAC filters.
To clean the brushes simply, disconnect the power. Remove the Air Ionizer if there is no
immediate access to the brushes. The brushes can be cleaned using compressed air or a
clean rag to dislodge any accumulated dust.