background image

Specification

Digital Multimeter

www.ultrics.uk

04

2. DC Current

10A range does not guarantee fuse protection, 10s at most.

Input impedance: 450k Ω
Frequency range: 40HZ-400HZ
Overload protection: peak value 600V for AC virtual value
Reveal: Average (the average of the virtual value of sine)

5. Diode Test

Test voltage approx 2.8V, current 1.5mA
Indicate forward voltage drop of diode unit: k Ω

7. Continuity test

Test voltage approximate 2.8V, current 1.5mA
The buzzer will beep when conductance resistance approximate<30

Range

mA 1.5 V

2 mA

20 mA

200 mA

10 A

Accuracy

2

(1.2%+2)

+-

(2.0%+2)

+-

(1.4%+2)

+-

Resolution

Only can test 1.5V battery current

1 uA

10 uA

100 uA

10 mA

4. Resistance

Range

200 Ω

2k Ω

20k Ω

200k Ω

2M Ω

Accuracy

(0.8%+5)

+-

(1.0%+2)

+-

Resolution

1 Ω

0.1 Ω

10 Ω

100 Ω

1 k Ω

6. Transistor hFE Test  

Range

NPN & PNP

1b=10uA

Vce=3V

Test Range

Test Current

Test Voltage

0-10000

3. AC Voltage

Range

200V
600V

Accuracy

(1.5%+8)

+-

Resolution

100 mA

1 V

Summary of Contents for UT0021YB

Page 1: ...USER GUIDE Digital Multimeter...

Page 2: ...tting electric shocks Before opening the back cover must pull out the test leads After closing the back cover and screwing it back it can carry on measuring Be sure that it is done properly Before rot...

Page 3: ...Input impedence 1M Automatic polarity display range instruction and battery changing indicator Power supply 9V battery NEDA 1604 6F22 type or equivalent type Environment condition Working temperature...

Page 4: ...ward voltage drop of diode unit k 7 Continuity test Test voltage approximate 2 8V current 1 5mA The buzzer will beep when conductance resistance approximate 30 Range mA 1 5 V 2 mA 20 mA 200 mA 10 A Ac...

Page 5: ...ge if can t sure choose the highest range 3 Connect the probes to the correct test points of the circuit to measure the voltage 4 Read the measured voltage on the display 2 Measure DC current 1 For cu...

Page 6: ...age at the resistance mode 5 Measure Continuity 1 Insert the red test lead to the V mA terminal and the black test lead to the COM terminal 2 Turn the rotary switch to position 3 Touch the probes to t...

Page 7: ...One pair of test leads 3 Manual 4 9V 6F22 battery Be cautious about the condition of the meter and the testing leads before using Please turn off the item when it is not in use in order to prolong it...

Page 8: ...ssional products in the world We will de nitely continue to innovate and challenge old paradigms with new solutions www weareheretohelp co uk Thank you for being with us Stay connected Support Registe...