Front Panel (Please see the panel)

1. LCD display, 1999digits

2. Buttons

 

i. Hold: To hold the current reading, press this button and you will see "H" on the display,    

 

press again to cancel.

 

ii. Display Backlight: To turn on the display light.

3. Rotary switch: To change mode or range.
4. V/Ω/mA: Input terminal for Voltage resistance, current (mA) diode, continuity measurements.
5. COM: Common Terminal for all Measurements.
6. 10A: Input terminal for related current measurements.

(1) Measure AC/ DC voltage

1. Insert the red test lead to the "VΩmA" terminal, and the black test lead to the "COM" terminal;
2. Turn the rotary switch to the DC voltage mode, or the AC voltage mode, choose the suitable               

range if can't sure, choose the highest range.

3. Connect the probes to the correct test points of the circuit to measure the voltage;
4. Read the measured voltage on the display.

(2) Measure DC current

1. For current less than 200mA, insert the red test lead to the "VΩmA" terminal, if current is more 

than 200mA, insert the red test lead into "10A" terminal, and the black test lead to the "COM" 
terminal.

2. Turn the rotary switch to the DC current related Mode.
3. Break the circuit path to be measured. Then connect the test leads across the break and apply 

power.

4. Read the measured current on the display

Caution:

a. Do not measure voltage exceeding the MAX value as indicated on the panel.
b. Do not touch the high voltage circuits during measurements.

Caution:

a. Do not measure current that exceeds the MAX value as indicated in the specifications;
b. Do not input voltage exceeds 36V DC or 25V AC when you are at the setting of measuring current.

Summary of Contents for UT0021YB

Page 1: ...USER GUIDE Digital Multimeter...

Page 2: ...tting electric shocks Before opening the back cover must pull out the test leads After closing the back cover and screwing it back it can carry on measuring Be sure that it is done properly Before rot...

Page 3: ...Input impedence 1M Automatic polarity display range instruction and battery changing indicator Power supply 9V battery NEDA 1604 6F22 type or equivalent type Environment condition Working temperature...

Page 4: ...ward voltage drop of diode unit k 7 Continuity test Test voltage approximate 2 8V current 1 5mA The buzzer will beep when conductance resistance approximate 30 Range mA 1 5 V 2 mA 20 mA 200 mA 10 A Ac...

Page 5: ...ge if can t sure choose the highest range 3 Connect the probes to the correct test points of the circuit to measure the voltage 4 Read the measured voltage on the display 2 Measure DC current 1 For cu...

Page 6: ...age at the resistance mode 5 Measure Continuity 1 Insert the red test lead to the V mA terminal and the black test lead to the COM terminal 2 Turn the rotary switch to position 3 Touch the probes to t...

Page 7: ...One pair of test leads 3 Manual 4 9V 6F22 battery Be cautious about the condition of the meter and the testing leads before using Please turn off the item when it is not in use in order to prolong it...

Page 8: ...ssional products in the world We will de nitely continue to innovate and challenge old paradigms with new solutions www weareheretohelp co uk Thank you for being with us Stay connected Support Registe...

Reviews: