DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-54-
Write Commands
Transmission data
Response data
Read
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0x2D
ACT
RESET ARC
COUNT
1byte
Resets the arc count.
Cumulative MARC, HARC count reset: 0x00
Cumulative MARC count reset: 0x01
Cumulative HARC count reset: 0x02
1byte
STATUS
0x2E
SET
ENABLE LARC
1byte
Enables/Disables the LARC function.
Disabled: 0x00
Enabled: 0x01
1byte
STATUS
0xC0
0x50
Option S
SET SS
1byte
Used to set the SS function.
It can be set in steps of 1.
1
~
5
→
1
~
5
1
:
0x01
5
:
0x05
1byte
STATUS
0xC1
0x51
Option A
SET
ENABLE
STOP
1byte
Used to set whether or not to stop the output during
arc processing.
Disabled (Low-output operation): 0x00
Enabled (Output stop): 0x01
1byte
STATUS
0xC2
0x52
Option S
SET
ENABLE RCV
1byte
Allows you to set whether or not to perform
automatic recovery after arc processing.
Disabled (without automatic recovery): 0x00
Enabled (with automatic recovery): 0x01
1byte
STATUS
0xC3
0x53
Option S
SET
RCV CRNT
2byte
Used to set the current value to be limited during
automatic recovery after arc processing.
It can be set in steps of 0.5 A.
Enter a value 10 times larger than the set value.
0.5A
~
5.0A
→
5
~
50
5
:
0x0005
50
:
0x0032
1byte
STATUS
0xC4
0x56
SET
SETPOINT
NORMAL
1byte
Used to set a tolerance ratio of 10% or more of the
rating for the setpoint
It can be set in steps of 1%.
2%
~
50%
→
2
~
50
2
:
0x02
50
:
0x32
1byte
STATUS
0xC7
0x57
SET
SETPOINT
FAIL
2byte
Sets the time until the SETPOINT is shifted to FAIL
if the SETPOINT is not output within the set time.
The setting is in 0.1s increments.
0.0s
~
60.0s
→
0
~
600
600
:
0x0258
1byte
STATUS
0xC8
0x58
Option C
SET
LEVEL HI-RES
2byte
Used to set the output command value.
Enter the value with a resolution higher than SET
LEVEL (0x12).
Only two units can be used at a maximum in system
connection.
The setting in each control mode is as follows:
For Current, enter a value 10 times larger than the
set value.
Power
0, 20
~
20000 (0x4E20)
20000W×1unit
0, 40
~
40000 (0x9C40)
20000W×2units
Voltage
0, 50
~
800 (0x0320)
0, 50
~
1000 (0x03E8)
HV spec.
Current
0, 5
~
500 (0x01F4)
50.0A×1 unit
0, 10
~
1000 (0x03E8)
50.0A×2units
1byte
STATUS
0xC9
Summary of Contents for DC-10-D
Page 87: ......