DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-60-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0x91
READ
LEVEL
2byte
Responds with the output command value.
The response value depends on the number of units
to be connected and the output control mode.
The output control mode can be confirmed by the
command (0x96).
The setting in each control mode is as follows:
For Power and Current, the system responds with a
value 10 times larger than the set value.
SET LEVEL HI-RES
(
0xC9) can be used to set even
higher resolution.
Power
0
~
200 (0x00C8)
20.0kW×1unit
0, 2
~
2400 (0x0960)
20.0kW×12units
Voltage
0, 50
~
800 (0x0320)
0, 50
~
1000 (0x03E8)
HV spec.
Current
0, 5
~
500 (0x01F4)
50.0A×1unit
0, 60
~
6000 (0x1770)
50.0A×12units
0x12
0x92
READ
POWER
2byte
Responds with the output value of the electric
power.
The value depends on the P/S configuration.
The output value is one tenth of the response value.
0.0kW
~
240.0kW
→
0
~
2400
2400
:
0x0960
0x93
READ
VOLTAGE
2byte
Responds with the output voltage value.
The value depends on the specifications.
0V
~
800V
→
0
~
800
0V
~
1000V
→
0
~
1000 (
HV spec.)
800
:
0x0320
1000
:
0x03E8
0x94
READ
CURRENT
2byte
Responds with the output current value.
The value depends on the P/S configuration.
The output value is one tenth of the response value.
0A
~
600.0A
→
0
~
6000
6000
:
0x1770
0x95
READ
CONTROL
MODE
1byte
Responds with the selected operation mode.
LOCAL mode (Front panel): 0x00
HOST mode (Serial communication): 0x01
USER mode (USER IO): 0x02
HST + mode (HST + USER ON)
0x03
CSTM mode (Optional setting): 0x04
0x13
0x96
READ
OUTPUT
MODE
1byte
Responds with the output control mode.
Power
:
0x00
Voltage
:
0x01
Current
:
0x02
0x14
0x97
READ
IGNITION
LIMIT
2byte
Responds with the limit value of the ignition voltage.
200V
~
1500V
→
200
~
1500
200
:
0x00C8
1500
:
0x05DC
0x16