DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-65-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0xCC
Option R
READ
RAMP
IGNITION
2byte
Responds with the rising time for ignition operation.
*Refer to [4-12. Description of Ramp Up Function.]
0, 10ms
~
10000ms
→
0, 10
~
10000
10000
:
0x2710
0x59
0xCD
READ
RAMP
NORMAL
2byte
Responds with the first rising time for output
operation.
*Refer to [4-12. Description of Ramp Up Function.]
0, 10ms
~
10000ms
→
0, 10
~
10000
10000
:
0x2710
0x5A
0xCE
Option A
Effective
range
available
READ
MARC
ACT
TIME
HI RES
2byte
Responds with the processing time for micro-arc
detection.
Responds with a resolution higher than READ
MARC ACT TIME (0xA5).
5us
~
50000us
→
5
~
50000
5
:
0x0005
50000
:
0xC350
0x5B
0xCF
READ
HARC
ACT
TIME
HI RES
2byte
Responds with the processing time for hard-arc
detection.
If the time is 0us, the micro-arc process is disabled.
Responds with a resolution higher than READ
HARC ACT TIME (0xA8).
0us, 100us
~
50000us
→
0, 100
~
50000
100
:
0x0064
50000
:
0xC350
0x5C
0xD0
READ
HARC
JUDGE
COUNT
HI RES
2byte
Responds with the micro-arc count before shifting
to the hard-arc process.
Responds with a resolution higher than READ
HARC JUDGE COUNT (0xA9).
1
~
50000 times
→
1
~
50000
50000
:
0xC350
0x5D
0xD1
READ
HARC
JUDGE
TIME
HI RES
2byte
Responds with the time required for the micro-arc
process to shift to the hard-arc process.
Responds with a resolution higher than READ
HARC JUDGE TIME (0xAA).
1ms
~
1000ms
→
1
~
1000
1000
:
0x03E8
0x5E
0xD2
READ
TOTAL
FAIL
COUNT
4byte
Responds with cumulative number of FAIL counts.
The maximum count is 99,999,999.
99,999,999
:
05F5E0FF
0xD3
READ
TOTAL
WARN
COUNT
4byte
Responds with the cumulative warning count.
The maximum count is 99,999,999.
99,999,999
:
05F5E0FF
0xD4
READ
LAST
WARN
COUNT
4byte
Responds with the warning count during the last
output operation.
The maximum count is 99,999,999.
99,999,999
:
05F5E0FF
0xD5
READ
LAST
HARC
COUNT
4byte
Responds with the hard-arc count during the last
output operation.
The maximum count is 99,999,999.
99,999,999
:
05F5E0FF