DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
2. Overview
-5-
2-5 Specifications
Table 2-3: Electrical specifications; 800V
Item
Specifications
Model
DC-10-D
DC-20-D
In
p
u
t
s
p
e
c
if
ic
a
ti
o
n
Rated input voltage
AC208V
Input voltage variation
range
AC187V
~
229V
Number of phases /
Frequency
Three-phase for 50/60Hz
Input connection
Connector
Input current*1
50A or less
80A or less
Input capacity*1
13.5kVA or less
25kVA or less
Leakage current
5 mA or less
Efficiency*2
87% or more
Power factor*2
0.85 or more
0.92 or more
O
u
tp
u
t
s
p
e
c
ifi
c
a
ti
o
n
Rated power
10kW
20kW
Rated current
25.0A
50.0A
Rated voltage
800V
800V
Ignition voltage
1500V
1500V
Output range
10kW
V1
1500V
V2
800V
V3
400V
I1
12.5A
I2
25A
*3
20kW
V1
1500V
V2
800V
V3
400V
I1
25A
I2
50A
*4
V1
1500V
V1
1500V
V2
800V
V2
800V
V3
400V
V3
400V
I1
12.5A
I1
25.0A
I2
25.0A
I2
50.0A
Output connection
Connector
*1: This depends on the working condition at your site.
*2: This depends on an input voltage of 187 to 229VAC. This may depend on the equipment on the input
side.
*3: 100V or more and 1A or more are the guaranteed output lower limit.
*4: 100V or more and 2A or more are the guaranteed output lower limit.
Summary of Contents for DC-10-D