DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
4. Description of Functions
-16-
4. Description of Functions
This section describes various functions of this power supply.
4-1 Name and Function of Each Part
4-1-1 Front panel
②
⑭
⑤
⑥
①
④
⑦
⑧,⑨,⑩,⑪
③
⑫
⑬
Figure 4-1: Front panel
Table 4-1: Name and function on the front
N
o.
Name
Shape
Function
①
ON button
LED (Green)
Push button
The LED lights up during the ON operation.
Even if the command value is 0, the LED lights up when the ON signal is received.
Only in the LOCAL mode, pressing the ON button in the READY state switches to the ON
operation.
The ON button is disabled in the other operation modes.
②
OFF button
Push button
Only in the LOCAL-mode operation, pressing the OFF button switches to the OFF operation.
In the other operation modes, holding down the OFF button triggers FAIL, switching to the
OFF operation.
③
Monitor
OLED
Displays command values, monitor values, various menu screens, etc.
④
ESC/ARC
button
Push button
This is mainly used when you would like to return to the previous menu screen.
Pressing the ARC button while holding down the FUNC button displays the number of ARC
processes on the front screen. Pressing the right button on the ARC screen also allows you to
check the total number of ARC processes.
⑤
ENT/RESET
button
Push button
This is mainly used to confirm values and menu selections on the menu screen.
Pressing the ENT button while holding down the FUNC button releases the FAIL state.
* If the FAIL state persists, the FAIL state occurs again even if the release operation has been
performed.
⑥
MENU/FAIL
button
Push button
This is mainly used when you would like to move from the top screen to the menu screen.
Pressing the FAIL button while holding down the FUNC button displays the FAIL history.
⑦
FUNC button
Push button
Use in combination with another button.
⑧
△
button
Push button
This is mainly used to increase setting values or move up the cursor on the menu screen.
⑨
▽
button
Push button
This is mainly used to decrease setting values or move down the cursor on the menu screen.
⑩
◁
button
Push button
Mainly increases the number of digits of setting values.
This is used to move the cursor to the left on the menu screen.
⑪
▷
button
Push button
Mainly decreases the number of digits of setting values.
This is used to move the cursor to the right on the menu screen.
⑫
LED
LED (Green)
INTERLOCK
Lights up when interlocks are released.
LED (Green)
READY
Lights up when ready to receive the ON signal.
LED (Green)
SETPOINT
Lights up when the monitor values are within their setting range with
respect to the command values.
LED (Orange)
ARC
Lights up when arc processing is performed.
LED (Red)
FAIL
Lights up when the FAIL state occurs.
⑬
USB for
mainteance
USB Type-C
It is a USB Port for maintenance. Do not use.
⑭
Fan inlet
-
This is the intake of the internal cooling FAN.
Summary of Contents for DC-10-D