6.1 Preventive Maintenance
Turn OFF the three-phase input power of the EB power supply before making
t
he following checks, except for items 1 through 3.
Table 6.1
Ite
m
Checks
Frequency of check
Remarks
Daily
Weekly Monthly
1 Does the electron beam gun flow
switch turn ON and OFF at the
specified flow rate? Here, does
the GUN WATER indicator turn
ON and OFF?
See
Note 1.
2 Does the CHAMBER indicator
light when the chamber is closed?
3 Does the VACUUM indicator light
when the chamber pressure has
lowered to below the preset value?
4 Is the electron beam gun insulator
contaminated or cracked and need
to be replaced?
See
Note 2.
5 Is the electron beam gun filament
worn out or deformed and need to
be replaced?
See
Note 2.
6 Is the electron beam gun filament
lead worn out by sputtering? Is
the filament lead connected firmly?
See
Note 3.
7 Is the lead of the electron beam gun
filament away from the filament by
more than 20 mm?
Is there short-circuit or broken wire
at the connection? Use care
especially after filament change.
See
Note 4.
8 Is the gun shield in the chamber
away from the filament by more
than 15 mm? (Use special care
when the filament is replaced.)
Summary of Contents for EGL-206M
Page 2: ...EB0007 03e...
Page 3: ...EB0007 03e...
Page 10: ......
Page 13: ...SECTION 1 3 Fig 1 1 Dimensional Drawing for EGL 206M EGL 406M...
Page 24: ...SECTION 3 14 Fig 3 1 Installation of two or more electron beam guns...
Page 26: ...SECTION 3 16 Fig 3 3 Typical water cooling piping arrangement...
Page 27: ...SECTION 3 17 Fig 3 4 Wiring arrangement in vacuum chamber...
Page 38: ...SECTION 5 28 Fig 5 1 Exploded view of emitter assembly and dimensional drawing for electrode...
Page 42: ...SECTION 5 32 Fig 5 2 Exploded view of EGL 206M EGL 406M...