Cooling water piping <Dismantling>
WARNING
Should you remove the Coolant joint immediately after having
stopped the Pump, there is a risk that the cooling water remained
inside the Pump comes to a boil and jets out. Keep flowing the
cooling water as far as the Pump temperature cools down.
The Pump is and remains very hot during and while after having
stopped operation. You have a risk of getting burned if a part of the
body touched it. Keep flowing the cooling water as far as the Pump
temperature cools down.
When you remove the pipes of coolant water, confirm that water does
not flow by a flowmeter (sight glass type) in the coolant water supply
such as devices.
Inlet / outlet port piping <Dismantling>
WARNING
Take off the piping following the Install Manual of the system.
The Inlet and outlet piping remains very hot while after having
stopped the Pump.
Be sure to take it off after the Pump has sufficiently cooled down.
Make airtight completely the Pump exhaust outlet with a blank flange.
Transfer
WARNING
You have a risk of giving damage to your back as the load larger than
safety standard shall be required to transfer the product.
PMB100D
:
26kg
PMB300D
:
51kg
PMB600D
:
82kg
PMB1200D
:
115kg
PMB2400D
:
260kg
Be sure to use the loading machinery (such as mobile crane) to lift up
the Pump or load it on the pallet and fix it and run the Pallet truck for
its transfer.
Never try to enter beneath the Pump unit when lifted it up.
Use sling belts to load/unload the unit.
Do not put the folk of the Fork lift or the like in the Pump bottom
(exhaust outlet) to lift it.
Note to purge the oil to transfer the pump. If forced to transfer
remaining the oil, be sure to keep the pump horizontal.
Do not tilt the pump 10 degree or more while you charge the oil.
The oil might run into the casing.
Summary of Contents for PMB100D
Page 2: ......
Page 3: ...Declaration of Conformity...
Page 39: ...YK11 0016 DI 002 08 12 2 4 Dimensional drawing Fig 11 Dimensional drawing PMB100D...
Page 40: ...YK11 0016 DI 002 08 13 Fig 12 Dimensional drawing PMB300D...
Page 41: ...YK11 0016 DI 002 08 14 Fig 13 Dimensional drawing PMB600D...
Page 42: ...YK11 0016 DI 002 08 15 Fig 14 Dimensional drawing PMB1200D...
Page 43: ...YK11 0016 DI 002 08 16 Fig 15 Dimensional drawing PMB2400D...
Page 62: ...YK11 0016 DI 002 08 35...
Page 65: ...YK11 0016 DI 002 08 38...
Page 72: ...YK11 0016 DI 002 08 45...
Page 84: ...YK11 0016 DI 002 08 57 Fig 28 PMB300D Optional attachment figure...
Page 85: ...YK11 0016 DI 002 08 58 Fig 29 PMB600D Optional attachment figure...
Page 86: ...YK11 0016 DI 002 08 59 Fig 30 PMB1200D Optional attachment figure...
Page 89: ...YK11 0016 DI 002 08 62 Fig 33 Dimensional drawing PMB2400D Horizontal exhaust model...
Page 99: ...YK11 0016 DI 002 08 72...
Page 105: ...YK11 0016 DI 002 08 78...
Page 119: ......