5.2.9 Checking Oil Mist Trap (option)
To use the Oil mist trap, be cautious not to have clog of the filter element in the trap. Too much
clog would prevent the exhaust gas from passing through the filter element, raise the pressure
inside the Pump unit and might result in breaking it.
Limit value of the pressure inside the Pump is 0.03MPaG (0.3kg/cm
2
G) (Gauge pressure).
We recommend you to install a Pressure monitor. Refer to the Instruction Manual of the oil mist
trap as for the install position of the pressure monitor. For the pressure monitor mounting
position, refer to Fig.17 or the instruction manual for the oil mist trap.
5.2.10 Checking drain valve
If you leave the drain valve with half opened for several months, it might get deformed that you
might not be able to shut the Pump all the way. When storing the Pump, please make sure the
valve is completely shut. If you are using the plug instead of valve, the same situation will be
applied.