SK00-4390-DI-002-11
10
3.2 Lubrication
Remove the oil filling plug and fill the pump with oil until the oil level comes between the two
level lines of the oil level gauge (MAX and MIN marks on the plate for the casted lines on the
pump case: Refer to the “Fig. 4 Lubrication and water piping drawing”).
The pump is operable if the oil level is between the two level lines of the oil level gauge during
operation.
CAUTION
Read “1. 2 Chemical Material Safety Data Sheet” previously before
starting lubrication.
Please obtain the latest version of Safety Data
Sheet (SDS) from our Sales Department.
Weal protective gears such as rubber gloves, protective goggle and so
on.
Should the oil touched to your hand are entered in your eye,
immediately follow the emergency treatment described on the SDS.
The oil level comes down approximately 1cm when operated the Pump.
Do not start the pump with the minimum level oil.
Ensure to use the vacuum pump oil designated by ULVAC. Operation
using oil other than designated shall be out of our scope of guarantee
as it might impair the pump performance and shorten the life cycle.
CAUTION
CAUTION
Summary of Contents for VS1501
Page 2: ......
Page 13: ...SK00 4390 DI 002 11 xi Fig 1 Warning Label display position...
Page 27: ...SK00 4390 DI 002 11 7 Fig 2 VS1501 Dimensional drawing...
Page 28: ...SK00 4390 DI 002 11 8 Fig 3 VS2401 Dimensional drawing...
Page 36: ...SK00 4390 DI 002 11 16 Fig 5 Suction Exhaust piping connection diagram...