SK00-4390-DI-002-11
17
3.6 Electrical Connection
Conduct the electrical connection referring to the Fig. 6, Fig.7 and Table 3.
Without changing motor, it is possible to run the Pumps both with 200V and 400V class utilities
by changing wire connection in the motor terminal box because multi voltage motor, for both
200V and 400V classes, is used for this pump
.
WARNING
Before wiring, please confirm the line voltage you use.
Please confirm the used line voltage and change crossline in the terminal
head.
Fig. 6 Recommended connection diagram
Fig. 7 Electrical wiring diagram
Summary of Contents for VS1501