INTRODUCTION
20
USER MANUAL — 74-36121-ENG R2
WARNING
• Grounding reliability can be achieved only when the bed is connected to a supply mains with protective
ground or to a hospital grade outlet that is protectively grounded.
• To avoid risk of electric shock hazard, bed must only be connected to a supply mains with protective
ground or to a hospital grade outlet that is protectively grounded.
• This bed is designed and intended for usage with a maximum total load of 600 lb/272 kg, including patient,
mattress and accessories. If not avoided, bed functionalities may not work properly and permanent
damages to bed may occur.
• This bed is not designed nor intended to be used with infants and/or toddler. If not avoided, situation could
become hazardous and prevention of patient fall or patient entrapment cannot be ensured.
• The bed exit detection system must be used with patients with minimum weight of 50 lb/22.6 kg and the
auto-arm function must be used with patient with minimum weight of 70 lb/31.8 kg. If not avoided, the bed
exit detection system may not detect all movements and the functionality of the detection system could be
affected.
• Prior to any operation or manipulation of the bed, always ensure that bed is clear of any physical impediments
including equipment, furniture, objects, wall, or a part of the body of the patient or another person. If not
avoided, moderated to severe injuries and/or permanent damages to bed or environment could occur.
• Always ensure proper clearance under the bed prior to use hoists, or other equipment, that slide under the
bed. If not avoided, moderated to severe injuries and/or permanent damages to bed or environment could
occur.
• It is the responsibility of the healthcare professionals to establish their contention techniques within their
facility and to ensure proper restraint straps usage, location and adjustment. Ensure that the configuration
of the bed and/or access to controls is safe for the patient. If not avoided, situation could result in patient
injury. The manufacturer does not issue any recommandations regarding the requirements and/or the
physical restraints used with patient, with any of its products.
• If siderails are used by patient as a grip handle, they shall be used with caution. Abusive usage could
result in bed tipping over and could result in moderate to severe injuries and damages to product and/or
environment.
• Siderails are not designed nor intended for patient restraint. If not avoided, situation could result in patient
injury.
• Do not use siderails to move the bed. If not avoided, situation could result in mechanical damages, which
could lead to patient fall. Use headboard or footboard to move the bed.
• CPR release option usage shall be restricted to emergencies. To avoid injuries or product damages, ensure
total clearance around product prior to usage.
• To reduce risk of fall and injury when patient is unattended, keep patient sleep surface to the lowest
position and siderails raised.
•
Always ensure the mattress used on bed complies with specifications of recommended mattresses. If not,
situation could become hazardous for patient fall or patient entrapment.
•
Verification, and maintenance of bed, and power cord adjustment shall be performed by qualified and
trained personnel. Electrical or electronic misconnection could result in shock or fire hazards.
!
Summary of Contents for OOK Snow FL36
Page 1: ...2 0 2 2 0 3 7 4 3 6 1 2 1 E N G R 2 User manual FL36 FL36 SC MH ...
Page 2: ......
Page 3: ...2 0 2 2 0 3 7 4 3 6 1 2 1 E N G R 2 User manual FL36 FL36 SC MH ...
Page 70: ......
Page 88: ......