OPERATING INSTRUCTIONS
34
USER MANUAL — 74-36121-ENG R2
Bumpers
Bumpers are located at each corner of bed to preserve wall. Each bumper offers a 3/4" socket to support IV poles.
Two optional bumpers are situated at head end of the bed for additional protection of the walls.
Bumpers with side view lights (optional)
Bumpers with integrated side view light system are located at both foot end corners of the bed. Foot end bumpers
offer a 3/4" socket to support IV poles. The green lights intensity can be controlled if the bed is equipped with
display screen; refer to the
section (page 45). The side view light system will indicate the
status of the bed exit system:
• lights off: bed exit is not in use
• solid green: bed exit is armed
•
flashing green: patient has been detected and bed will arm when patient is properly positionned in bed
•
flashing amber: bed exit has been triggered or motion interrupt has been triggered (if applicable)
• solid amber: bed exit is in pause mode (if applicable)
IMPORTANT
An audible signal can also be set; see bed exit control system settings in the
Footboard control
Power cord support brackets
Support brackets are available at the head end of bed (illustrated) to store the power
cord during transportation or when not in use.
Short power cord (optional)
The power cord length can be adjusted to meet the needs and condition of a patient in a specific environment. The
length of the short power cord is of 1 m / 40", but can be adjusted to a longer length if required. The label fixed on
the power cord always needs to be visible to ensure that the minimum length allowed for this option is respected;
do not remove the label from the power cord.
WARNING
•
Verification, and maintenance of bed, and power cord adjustment shall be performed by qualified and
trained personnel. Electrical or electronic misconnection could result in shock or fire hazards.
• Always ensure that usage of a power cord with reduced length is restricted only to patients with an
evaluated medical condition that requires extreme protection measures. Plug the power cord to a hospital
grade power outlet without the usage of an extension cord.
• The use of the removable patient control option is not recommended if option of short power cord applies
to a patient with an evaluated medical condition that requires extreme protection measures.
!
Summary of Contents for OOK Snow FL36