INTRODUCTION
USER MANUAL — 74-36105-ENG R5
19
• If electrical equipment is connected to the auxiliary outlet or USB port, ensure that any electrical device
introduced within the patient vicinity is not causing electrical interferences. The connected electrical
equipment could results in power leads or radiation emitting devices closer to the patient (ex: computer
charger, mobile phone) and their interference shall be managed to avoid biased diagnostics (ex: ECG
monitors) or limited treatment efficiency (ex: pacemakers).
•
The use of accessories, transducers and cables other than those specified, with the exception of transducers
and cables sold by the manufacturer of the medical electrical equipment or medical electrical system as
replacement parts for internal components, may result in increased emissions or decreased immunity of
the medical electrical equipment or medical electrical system.
• The medical electrical equipment or medical electrical system should not be used adjacent to or stacked
with other equipment and that if adjacent or stacked use is necessary, the medical electrical equipment or
medical electrical system should be observed to verify normal operation in the configuration in which it will
be used.
•
Do not use the fixed head and foot boards in intensive and critical care environments or acute care
environments. Use of fixed head and foot boards does not allow immediate and unimpeded access to the
patient from the head end of the medical bed in emergency situations. Patient’s medical condition must not
require immediate access for procedures (e.g. intubation).
• Always ensure that the accessories installed on the bed are adequate for the patient’s condition and would
not generate a risk in case of misuse by the patient.
• Always ensure that usage of a power cord with reduced length is restricted only to patients with an
evaluated medical condition that requires extreme protection measures. Plug the power cord to a hospital
grade power outlet without the usage of an extension cord.
ATTENTION
• Patient monitoring and patient-authorized bed functionalities are responsibility of the facility.
• Always ensure to unplug power cord from power outlet prior to move bed. If situation is not avoided,
damages to bed and/or to environment could occur.
• Always ensure of power cord proper condition prior to plug it into power outlet.
• Always ensure that when routing cables from other equipment or hoists in the bed, precautions are taken
to avoid them from being pinched between parts of the bed.
•
Connecting electrical equipment to the auxiliary outlet (optional) effectively leads to creating a medical
electrical system, and can result in a reduced level of safety.
• Always ensure proper product clearance in order to reach all the different device controls, boards,
accessories and electrical connections. In case of emergency, these systems should be easily reachable
to ensure timely procedure.
•
Always ensure to unplug any device from the auxiliary outlet (optional) prior to move bed. If situation is not
avoided, damages to bed and/or to environment could occur.
• Always unplug battery harness if bed is intended to be stored for 3 months or longer. If not avoided,
situation could result in an accelerated deterioration of the batteries.
• Bed, parts and accessories are not designed for a cleaning with usage of a hose, steam or ultrasounds.
Do not immerse any part of the bed. If not avoided, situation could result in permanent damages to bed.
!