background image

Checking the vertical line: 

Position the device about 5 m from a wall. Fix a

plumb bob with a line of 2.5 m length on the wall, making sure that the bob
can swing freely. Switch on the device and align the vertical laser to the plumb
line. The precision is within the specified tolerance if the deviation between the
laser line and the plumb line is not greater than ± 1.5 mm.

Checking the horizontal line:

Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the wall.
Turn the laser cross approx. 2.5 m to the right and
mark point C. Check whether the horizontal line
from point C is level with point B to within ± 2 mm.
Repeat the process by turning the laser to the left.

AutoCross-Laser ACL 3 RX

ENGLISH 

14

Performing the calibration check:

3.

Position the device as near as possible to the wall at the height of

point  A1.

4.

Turn the device 

through 180° and
mark point A3. The
difference between
points A2 and A3 is
the tolerance.

Preparing the calibration check:

It is possible for you to check the calibration of the laser. To do this, position
the device 

midway

between 2 walls, which must be at least 5 metres apart.

Switch the device on 

(LASER CROSS AND TILT FUNCTION ON)

. Please use

a tripod. 

1.

Mark point A1 on the wall.

2. 

Turn the device 

through 180° and
mark point A2.
You now have a
horizontal reference
between points A1
and A2.

180°

180°

A1

A2

2.

1.

Note:

If points A2 and A3 are more than 2 mm / 10 m, the device is in

need of calibration. Contact your authorised dealer or else the UMAREX-
LASERLINER Service Department.

B

C

2,5 m

<

2 mm = OK

A3

180°

180°

A2

A3

A2

A2

A1

4.

3.

<

2 mm / 10 m = OK

Summary of Contents for LaserLiner AutoCross-Laser ACL 3 RX

Page 1: ...perating instructions Gebruiksaanwijzing Betjeningsvejledning Mode d emploi Instrucciones para su uso Istruzioni d uso Instrukcja Obs ugi K ytt ohje Instru es de uso 3 8 9 14 15 20 21 26 27 32 33 38 3...

Page 2: ...2 AutoCross Laser ACL 3 RX...

Page 3: ...bration before use after transport and after extended periods of storage We also wish to point out that absolute calibration is only possible in a specialist workshop Calibration by yourself is only a...

Page 4: ...12 13 14 15 16 Laser exit window Control panel Battery compartment on back ON OFF switch Transport securing device 1 4 thread ACL 3 RX bottom of housing Base rotatable 5 8 thread bottom of housing Ad...

Page 5: ...tivated button 13 tilt control lamp 12 off The lasers will now shine continuously even if the device is positioned at an angle for generating a slope gradient For horizontal and vertical levelling rea...

Page 6: ...d receiver mode button 10 The laser lines will now pulsate with high frequency 10 kHz making the laser lines darker The laser receiver can detect these pulsating laser lines up to a maximum distance o...

Page 7: ...ularly check the calibration before use after transport and after extended periods of storage Technical data Self levelling range 4 5 Precision 2 mm 10 m Working range with laser receiver max 50 m Las...

Page 8: ...AutoCross Laser ACL 3 RX ENGLISH 14 Performing the calibration check 3 Position the device as near as possible to the wall at the height of point A1 4 Turn the device through 180 and mark point A3 The...

Page 9: ...www laserliner com max ca 330 cm Art Nr 023 61A Zubeh r optional Accessories optional Accessoires optioneel Tilbeh r flere typer Accessoires en option GB D NL DK E I PL FIN Accesorios opcional Access...

Page 10: ...932 638 333 Huolto ja l hetysosoite Puhelin 49 2932 638 300 Fax 49 2932 638 333 Endere o de servi o p s venda Telefone 49 2932 638 300 Fax 49 2932 638 333 Service und Versand Anschrift Service Telefon...

Reviews: