background image

17

WARRANTY INFORMATION

UMF Medical warrants to the original purchaser a warranty 
for products to be free from functional defects in material 
and workmanship under normal interior use and service. UMF

 

Medical’s obligation under this warranty is limited to the 
repair or replacement, at UMF Medical’s option, of the parts 
or the products the defects of which are reported to UMF 
Medical within the applicable warranty period and which upon

 

examination by UMF Medical prove to be defective. Warranty

 

subject to the terms and conditions listed below.

Length of warranty, measured by Purchase Date (Invoice Date),

 

for all warranted products and components:

Five years:

Signature Series Examination Tables 
(52xx model numbers and Treatment and 
Orthopedic Tables (55xx model numbers). 
Ultra-Comfort adjustable backrest cylinder 
not included.

Three years:

Power Exam and Procedure Tables and all 
other UMF Medical products excluding the 
products listed in Five Year and One Year 
categories of this document.

One year: 

Waste Receptacles, Bassinet Baskets, 
Bassinet Mattresses and ultra-comfort 
adjustable backrest cylinder. 

Obtaining Warranty Service 

Warranty service must be obtained by contacting either 
the Authorized Distributor through whom the product was 
purchased or UMF Medical Customer Service Department via

 

phone at 814-266-8726, or via email at customerservice@
umfmedical.com.
This warranty covers the cost associated with the repair parts 
only and does not cover any other charges, including but not 
limited to service calls, labor, transportation, shipping, etc. 
It is the retail customer’s obligation to arrange delivery of a 
product to UMF Medical or one of its authorized distributors

 

for warranty service, which delivery shall be at the retail 
purchaser’s expense. It is also the retail purchaser’s obligation 
to comply with the warranty service instruction provided by 
UMF Medical or its authorized distributor. The retail purchaser

 

must provide UMF Medical with completed warranty registration

 

information within thirty days after purchase in order to obtain 
the benefits of this warranty.

Limited warranty general exceptions and exclusions

This warranty does not cover and UMF Medical shall not be 
liable for the following:

› 

Parts and products of a consumable nature;

› 

Defects, damage or other conditions caused, in whole or in 
part, by mishandling, misuse, abuse, negligence, alteration, 

accident, freight damage, tampering or failure to seek

 

and obtain repair or replacement in a timely manner;

› 

Products which are not  installed, used, and properly cleaned 
and maintained as required in the UMF Medical installation 
and/or Owner’s Manual for the applicable product;

› 

Replacement parts, alterations or installation of any 
accessories or parts not manufactured or recommended

 

by UMF Medical;

› 

Cosmetic and non-functional defects not noted at time

 

of delivery.

› 

Charges for repairs, replacement parts, adjustments, 
installation or other work performed upon or in connection 
with products which are not expressly authorized in writing 
in advance by UMF Medical.

› 

Damages resulting from inadequate power supply (including

 

incorrect voltage, voltage spikes or other irregularities) or 
use or storage in corrosive atmospheres.

To the extent any or all of the following exclusions or 
provisions of this warranty are prohibited by any federal, state, 
or municipal law which cannot be preempted, those exclusions 
or provisions shall not be applicable.

Exclusive Remedy: Consequential Damages Disclaimer

UMF Medical’s only obligation under this warranty is the repair

 

or replacement of defective parts. UMF Medical shall not be 
liable for and hereby disclaims any direct, special, indirect, 
incidental, exemplary or consequential damages or delays, 
including but not limited to, damages for  loss of profits or 
income, loss of use, downtime, employee or independent 
contractor wages, payments and benefits, commercial loss

 

or other incidental charges.

No Authorization

No person or firm is authorized to create or approve for

 

UMF Medical any other obligation or liability in connection

 

with the products.

Warranty Disclaimer

THIS WARRANTY IS UMF MEDICAL’S ONLY WARRANTY 
AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED. UMF MEDICAL MAKES NO IMPLIED WARRANTIES 

OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES 
OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR 

PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR 
REPLACEMENT OF DEFECTIVE PARTS.

 

No action may be brought against UMF Medical for breach 
of this limited warranty, an implied warranty, if any, or for any 
other claim arising out of or relating to the products following 
expiration of the limited warranty period.

 

UMF Medical reserves the right to make changes in the design 
or material of its products without incurring any obligation 
to incorporate such changes in any product previously 
manufactured.

Summary of Contents for 4010-650

Page 1: ...ACTURE MAXIMUM PATIENT WEIGHT 650 LBS 295 KG OWNER S MANUAL POWER PROCEDURE CHAIR 4010 650 4011 650 5016 650 UMFmedical com Ph 814 266 8726 Fax 814 266 1870 1316 Eisenhower Blvd Johnstown PA 15904 cus...

Page 2: ...ent loading 1 minute on 9 minutes off or 2 minutes on 18 minutes off This product has been evaluated with respect to electrical shock fire mechanical hazards only in accordance with UL60601 1 and CAN...

Page 3: ...60HZ 9AMP Electrical Supply Optional 220V 60HZ 5AMP Power Cord Length 10 FT 3 0m Table Weight 450 lbs 204kg Paper Roll Maximum size 21 0 Long x 3 5 Diameter 53 3 cm x 8 9 cm Caster Base Clearance 0 2...

Page 4: ...cal Supply Standard 120V 60HZ 9AMP Electrical Supply Optional 220V 60HZ 5AMP Power Cord Length 10 FT 3 0m Table Weight 470 lbs 213kg Paper Roll Maximum size 21 0 Long x 3 5 Diameter 53 3 cm x 8 9 cm C...

Page 5: ...cal Supply Standard 120V 60HZ 9AMP Electrical Supply Optional 220V 60HZ 5AMP Power Cord Length 10 FT 3 0m Table Weight 470 lbs 213kg Paper Roll Maximum size 21 0 Long x 3 5 Diameter 53 3 cm x 8 9 cm C...

Page 6: ...n order to prevent misuse when staff is not present Patient Safety Table Lockout To lock and unlock FOR MAXIMUM PATIENT SAFETY LOCK TABLE IMMEDIATELY AFTER EACH USE WARNING Procedure Chair Four Functi...

Page 7: ...Control FEATURES AND OPERATION Hand Foot Control Table Operation DO NOT USE BACKREST AS A SEAT WARNING Height Adjustment Backrest Adjustment Pelvic Tilt Adjustment Legrest Adjustment Home Shown with...

Page 8: ...functions Simultaneous Movement shown as an example To Program 1 Move table to desired position for memory storage 2 Press and hold approximately 3 seconds desired memory position button M1 or M2 in w...

Page 9: ...paper to desired length 1 Pull the stirrups out and unfold 2 Lift slightly and move left or right to position DO NOT SUPPORT THE PATIENT S ENTIRE WEIGHT WITH THE STIRRUPS WARNING DO NOT RAISE LEGREST...

Page 10: ...d Rest 1 Squeeze adjustment button 2 Position the Headrest 3 Release adjustment button to lock headrest in desired place 4 Adjust friction knob so headrest slides smoothly or to lock into position FEA...

Page 11: ...ature 1 Plug into the hand control port 2 Turn the union nut clockwise until fully threaded Back Left to Right 1 Foot control port 2 False Port 3 Hand control port 4 Power on LED 5 Power cord port Fro...

Page 12: ...E IS NOT TO BE USED FOR PATIENT TRANSPORT ENSURE WHEELS ARE IN PATIENT READY POSITION PRIOR TO A PATIENT ACCESSING TABLE TABLE IS NOT TO BE USED FOR PATIENT TRANSPORT CASTERS ARE TO BE USED SOLELY WHE...

Page 13: ...13 Multi Positioning Armrests COMMON OPTIONS AND ACCESSORIES Shown with arm rest accessory...

Page 14: ...MAY LEAD TO A REDUCED LEVEL OF SAFETY OF THE RESULTING SYSTEM OUTLET IS FOR MEDICAL EQUIPMENT ONLY CAUTION CHECK GROUND CONTINUITY PERIODICALLY 120V MAXIMUM OUTPUT 5 0A 120V 220V MAXIMUM OUTPUT 2 5A 2...

Page 15: ...otrol BirexSE Bleach 1 5 20 bleach Bleach 1 9 10 bleach Bleach Rite Disinfecting Spray CaviCide CaviCide1 CaviCide AF Diversey Accel INTERVention Wipes Diversey Avert Sporicidal Disinfectant Cleaner E...

Page 16: ...Facilities for bleach alternative cleaners Note Immediately remove any fluid spilled on upholstery surface Antimicrobial UMF Medical Upholstery providers outstanding protection in difficult medical a...

Page 17: ...in whole or in part by mishandling misuse abuse negligence alteration accident freight damage tampering or failure to seek and obtain repair or replacement in a timely manner Products which are not i...

Page 18: ...the ports and choose which port to plug in your foot control 2 The table has one 1 port for the hand control located in the rear of the table base 3 Start with installing the hand control 4 Locate th...

Reviews: