UMF Medical 

www.umfmedical.com

 

 

1  IMPORTANT INFORMATION 

 

1.1 READ THIS FIRST! 

1.1.1  Safety  First:  The  primary  concern  of  UMF  Medical  is 

that  this  equipment  is  operated  and  maintained  with 
the safety of the patient and doctor in mind. 

1.1.2

 

WARNING: 

Personal injury can result from 

improper maintenance or repairs.  Only persons 
specially trained and qualified in the maintenance and 
repair of medical furniture and equipment should 
service this equipment.  UMF Medical assumes no 
responsibility for improper repair or maintenance of its 
products.  

 

1.1.3

 

If you encounter an issue which is not covered in this 
service manual, please contact the technical service 
department at UMF Medical for assistance.  Under no 
circumstances should this table be modified from its 
original design, nor should it be used for purposes 
other than those for which it was originally designed.  
Failure to adhere to these requirements voids the 
warranty on this product.

 

 

1.2 ENVIRONMENTAL CONDITIONS 

Transport and storage temperature range: -20°C to 40°C 
Maximum transport, storage, or operating humidity: 95% 
Standard operating temperature range: 0°C to 40°C 

1.3 CLASSIFICATIONS

 

Protection against electric shock:

 Class I, Class B Applied Parts  

Protection against harmful ingress of water:

 Ordinary  

Mode of Operation:

 Continuous operation  

Equipment is not suitable for use in the presence of a 

flammable anesthetics mixture with air or with oxygen 
or with nitrous oxide  

 
1.4 SAFETY SYMBOLS 

WARNING

 

The 

warning 

symbol 

identifies 

special 

instructions or procedures, which if not correctly 
followed could result in personal injury. 

CAUTION

 

The caution symbol identifies special instructions 
or  procedures,  which  if  not  correctly  followed 
could result in danger or damage of equipment. 

 

UL  Classification  mark  with  respect  to  electric 
shock,  fire,  and  mechanical  hazards  only  in 
accordance with UL60601-1 

 

 

Attention, consult accompanying documents 

 

 

Type B, Applied Part 

Summary of Contents for 5005

Page 1: ...12 2011 UMF Medical 1316 Eisenhower Blvd Johnstown PA 15904 814 266 8726 WWW UMFMEDICAL COM 5005 Bariatric Power Treatment Table Service Manual...

Page 2: ...R 5 3 1 NONE OF THE FUNCTIONS ON THE TABLE ARE WORKING WHAT SHOULD I DO 5 3 2 THE POWERED BACK SECTION IS NOT MOVING WHEN ACTIVATED WHAT SHOULD I DO 6 3 3 THE TABLE IS NOT MOVING UP AND DOWN WHAT SHOU...

Page 3: ...igned Failure to adhere to these requirements voids the warranty on this product 1 2 ENVIRONMENTAL CONDITIONS Transport and storage temperature range 20 C to 40 C Maximum transport storage or operatin...

Page 4: ...ty is limited to the duration of the express warranty herein United Metal Fabricators Inc d b a UMF Medical shall not be liable for the loss of the use of this product inconvenience loss or other dama...

Page 5: ...f the unit has power 3 1 4 1 If the light is not on check the facility s circuit breaker If all plugs are correct and the circuit breakers are working properly replace the control box see section 3 1...

Page 6: ...damage Inspect all wires that are readily visible for signs of cuts tears or other damage that could cause a loss of communication between components 3 2 3 Check plugs Check all plugs and connections...

Page 7: ...ight clicking noise If the noise is not heard when activating the up down button replace the hand control see section 3 1 8 3 3 5 Replace Control Box See section 3 1 7 3 3 6 If this does not work cont...

Page 8: ...emove the bolts from the base to completely detach the actuator 3 4 2 2 11 Install the new actuator onto the base by reinstalling the four bolts on the bottom of the actuator CAUTION Ensure that the n...

Page 9: ...TS LIST AND EXPLODED VIEW Actuator Actuator Upholstered top includes the foot section 2 function Hand Control Control Box Actuator and attachment bracket Top Cover Footstep assembly Base Base Drawer a...

Page 10: ...NPN Control box 063 2 function Hand Control 069 2 function Foot Control Accessories 035 Arm board assembly contains 1 each 036 038 and 039 036 Sliding bracket and lug reversible required for the 038...

Page 11: ...the serial number of the table and contact your authorized UMF Medical distributor If you are unsure of your authorized distributor please contact UMF Medical customer service at UMF Medical 1316 Eis...

Page 12: ...iately remove any fluid spilled on upholstery surface CAUTION When the use of rubbing alcohol is necessary first test in an inconspicuous area to ensure that damage to upholstery will not occur PAINTE...

Reviews: