Umirs Europe Ltd. Predix
- 12 -
TECHNICAL SPECIFICATIONS
Specification
Value
Detection zone length
10-400 m
Minimum required level of signal received at maximum length of the
DETECTION ZONE
8 dB
Minimum detection zone height for a protected segment length of
300m
2.5m
Range of detection speeds
0.1-10.0 m/s
working supply voltage, V-DC
12-36 VDC
Maximum current required at the working supply voltage of
12V/24V/36V,
а) “Predix” transmitter unit
b) “Predix” receiver unit
128mA/61mA/56mA
170mA/85mA/
56mA
Maximum operable time after the supply is switched on
12 s
Maximum recovery time of the stand-by system after notification of
an alarm
10 s
Parameters of signal, switched with the contacts of the output
circuit:
-
maximum current, constant or alternate
-
maximum amplitude voltage
30 mA
72 V
RC signal parameters:
-
maximum input resistance of the circuit
-
impulse voltage
-
maximum impulse duration
5 kΩ
10-30 V
0.5 s
Minimum signal duration
5 s
Operating frequency
24.00-24.25 GHz
Overall dimensions of
Predix 50-100 with bracket:
Predix 200-300-400 with bracket:
165х165х180 mm
100x230x180 mm
Maximum weight of the packaged detector
1,8kg
Minimum average service life of the detector, years (warrantied)
2