4

   

The   sprinkler   is   

not

   

reaching   the   
expected   radius

   

The   delivery   
pressure   to   the   
sprinkler   is   too   low.   
   
   
   
   
   
The   sprinkler   main   
nozzle   is   the   
incorrect   size   or   is   
clogged.   
   

Depressurize   the   
mainline   or   sub-­‐
lateral   piping   
before   attempting   
the   last   two   
possible   root   
causes   

   
The   bottom   inlet   
filter   is   clogged   with   
debris.   

Verify   delivery   pressure   with   a   
Pitot   tube   and   pressure   gauge   
while   the   sprinkler   is   operating.   
   
Is   the   operating   pressure   
matching   the   design   pressure   
indicated   on   the   drawings?      
   
Verify   the   nozzle   size   that   is   
molded   into   the   side   of   the   nozzle   
body.      Remove   and   verify   no   
debris   is   blocking   the   nozzle   port.   
   
   
   
   
   
   
   
   
   
Disassemble   the   sprinkler   and   
remove   the   foot   valve.      Inspect   the   
inlet   screen   and   remove   any   
accumulated   debris,   then   re-­‐
assemble.   

   

   

   

!   

Summary of Contents for Mirage M-125

Page 1: ...M 125 M 115 Operating and Maintenance Instructions Underhill International Corporation 20505 Crescent Bay Drive Lake Forest CA 92630 Phone 949 305 7050 Fax 949 305 7051 www uicorp net www underhill us...

Page 2: ...1 DEFINITION OF SYMBOLS 3 2 2 DANGER IF SAFETY INSTRUCTIONS ARE NOT OBSERVED 4 3 0 DESCRIPTION 4 4 0 INSTALLATION 4 5 0 COMMISSIONING 4 6 0 WINTERIZING 5 7 0 MAINTENANCE 5 8 0 INSPECTION AND DISASSEM...

Page 3: ...ull 3600 or part circle to a minimum of 300 The Mirage M 125 M 115 can be applied in both synthetic and natural turf applications Both products have a 1 1 2 BSP inlet threads and can be mated with Und...

Page 4: ...provided PVC or ductile iron swing joint assembly 5 Once the sprinkler head is installed set vertically and to adjacent finish grade Make the wire connections for valve in head models using approved...

Page 5: ...ater can be flushing from the solenoid plunger chambers 4 During the winter it is recommended to activate the solenoid for about 1 minute 2 times a week 7 0 Maintenance 1 Clean the interior cavity of...

Page 6: ...Mirage M 125 M 115 Operating Maintenance Instructions 6 M 125 M 115 Sprinkler Subassemblies Figure 6 1 1 2 3 5 4 6 7...

Page 7: ...s threaded plate to the side 2 Locate and unscrew the slotted head fasteners that secure the impact drive assembly to the lower portion of the sprinkler body Set the fasteners to the side and carefull...

Page 8: ...the valve sleeve tool p n RZK2 17623 Insert into the lower sprinkler body with the chamfered surface pointing downward Grease the rubber edges to ease of insertion 2 Align the valve insert with manua...

Page 9: ...impact drive assembly are set to arc pattern desired 6 Place the brass threaded plate and secure the top lid to the plate using the 2 qty Allen head fasteners 7 Operate the re assembled sprinkler eit...

Page 10: ...is inadequate De pressurize the mainline or sub lateral piping before attempting the last two possible root causes The solenoid is defective The plunger in the solenoid is stuck in the up position Re...

Page 11: ...compressed air blow the control pipe backwards to remove any clogged debris 3 Sprinkler will not turn off manually De pressurize the mainline or sub lateral piping before attempting the last two poss...

Page 12: ...possible root causes The bottom inlet filter is clogged with debris Verify delivery pressure with a Pitot tube and pressure gauge while the sprinkler is operating Is the operating pressure matching t...

Reviews: