18
caldoungaro.it
documents:
1. Purchase invoice;
2. Electrical Certificate of Compliance;
3. Declaration of Chimney Conformity.
9.3 Documents to ask to Authorized
Technician
At the end of intervention the technician
will give:
1. Service Log signed;
2. Invoice for the used spare parts for
out of warranty interventions.
Ungaro S.r.l. reminds that the
manufacturer is the holder of
the rights provided by Leg. D.
02/06/2002 and the guarantee
does not affect these rights.
10. Technical Data
Model
6kW
9kW
12kW
Heat Input
Max kW
6,3
8,1
11,4
Min
kW
2,7
2,7
2,7
Air Heat
Output
Max kW
5,7
7,3
10,1
Min
kW
2,5
2,5
2,5
Efficiency
P.max %
90,5
90
88,7
P.min %
93,2
93,1
92,8
Consumption
P.max kg/h
1,3
1,7
2,4
P.min kg/h
0,5
0,6
0,6
Pellet tank
kg
22
22
22
Flue pipe
A
Ø
mm
80
Primary air
pipe
B
60
Ductable air
C
80